ENGLISH
ACTIVE STANDBY :
This function allows the machine to enter stand-
by mode or not, which makes it possible to
choose whether or not to switch off the machine
completely or to keep it at a set pressure (less
than working levels).
Use the rotary switch to select the following
options:
OFF: during the OFF state, the machine is
completely switched off and the display
reads "OFF"
Active standby
0.10 bar
Active standby
ON 0.10 bar: during the OFF state, the
machine maintains a pressure of 0.10 bar
and the display (set to minimum brightness)
reads "LOW CONSUMPTION".
0.50 bar
Active standby
0.80 bar
Active standby
ON 0.50 bar: during the OFF state, the
machine maintains a pressure of 0.50 bar
and the display (set to minimum brightness)
reads "LOW CONSUMPTION.
Press the rotary switch to confirm the required
option.
This operation is used with both manual switching
on/off using the button
, and automatic
switching on/off by programming the machine.
If the on/off button
,
is pressed during one of
the three active standby states (0.10 bar, 0.50
bar, 0.80 bar), the machine will switch off com-
pletely.
If the button is pressed again, this will switch on
the machine.
7.2.6
DELIVERY COUNT
Use the rotary switch to move to the "Delivery
count" icon and press to open:
Main Menu
Language Dose
programming
Temperature
setpoint
Key and display
settings
Energy
saving
Pour
count
Alarms
Technical
settings
ure
t
Key and display
sett
ings
T
echnical
settin
g
s
setp
oin
Alarms
t
Energy
y and disp
and
disp
emperature
u
Dose
Language
ge
Dose
prog
g
ramm
ing
Tem
s
P
our
c
oun
t
A
s
A
A screen will open to view the counters:
Pour count
Pour count
P
our
cou
n
t
Select the delivery counter icon and
press the rotary switch.
On the counter page, it is possible to view 2
tables that show the counters; to pass from one
to the other, use the rotary switch.
The first table shows the counts for the single
doses of each group:
Continue 1
0
0
0
5
0
0
0
0
0
0
0
0
0
0
0
3
3
5
Cont
inue
ON 0.80 bar: during the OFF state, the
machine maintains a pressure of 0.80 bar
and the display (set to minimum brightness)
reads "LOW CONSUMPTION"

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nuova Simonelli Aurelia II Digit T3 and is the answer not in the manual?

Nuova Simonelli Aurelia II Digit T3 Specifications

General IconGeneral
BrandNuova Simonelli
ModelAurelia II Digit T3
CategoryCoffee Maker
LanguageEnglish

Related product manuals