7.2.3
SET POINT
TEMPERATURE
Use the rotary switch to move to the "Set point
temperature" and press to enter:
4 options will be displayed:
Icon Description
Group setpoint
(T3 version only).
Setpoint caldaie
(solo versione T3).
Steam boiler setpoint.
Cup warmer.
GROUP SETPOINT (T3 version only)
:
The display will show:
Group offset
1.0
1.0 1.0
3
3
93.894.0
109.6
93.8
109.6110.8
Group setpoint
Group temperature
Group setpoint
94 0
3
3
Use the rotary switch to select the coffee group
to adjust and confirm by pressing.
Turn the rotary switch to select the required
temperature for the group, then press to con-
firm.
Group 1 example:
GROUP OFFSET ADJUSTMENT:
From the screen:
Hold down the washing key
to access
offset and group temperature adjustment.
The next screen will be:
With the rotary switch it is possible to select the
group offset to be adjusted and press to pro-
ceed.
Use the rotary switch to adjust the value of the
group offset and then confirm with by pressing
the switch.
At this point, it is possible to adjust the offset of
the other groups with the same procedure or to
select
Menu
or
Home
.
This setting is reserved to qualified service
engineers.
Group setpoint
93.8
94.0
92.8
93.8
92.892.0
Group temperature
Group setpoint
3
3
Group setpoint
93.8
94.0
92.8
93.8
92.892.0
Group temperature
Group setpoint
3
3
Setpoint
Group
setpoint
Boiler
setpoint
Steam boiler
setpoint
Cup warmeroil
er
etp
o
i
n
t
e
a
m bo
tp
o
i
n
t
t
St
e
se
t
G
rou
p
set
p
o
i
n
t
t
B
se
Setpoi
nt
u
p
warmer
o
iler
C
Main Menu
Dose
programming
Temperature
setpoint
Key and display
settings
Energy
saving
Pour
count
Alarms Technical
settings
Language
y and disp
lay
settin
g
s
s
T
ec
h
n
i
ca
l
settin
g
s
Alarms
s
programm
Pour
Ener
gy
y
and
disp
y and
dis
Dose
Language
M
ming
Temperature
setpoin
Key
t
ure
nt
Key
setpoin
nt
ming
Key
y
Instant setting
Setting programmed
/ to be programmed

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nuova Simonelli Aurelia II Digit T3 and is the answer not in the manual?

Nuova Simonelli Aurelia II Digit T3 Specifications

General IconGeneral
BrandNuova Simonelli
ModelAurelia II Digit T3
CategoryCoffee Maker
LanguageEnglish

Related product manuals