4307 & 4310 Blower | 17
The intake and exhaust system can be plumbed with 4” or 6” hose. Four inch hose
will provide a more compact system while the 6” hose will maximize the eciency of
the system.
The ballast system should be plumbed using 4” hose minimum. Be sure to locate the
ballast inlet away from heat, debris and uid sources as exposure to these may result
in damage to the blower.
Recommended Accessories
Exhaust Silencer
Posive displacement blowers are inherently noisy due to their design. NVE oers
compable silencers for the exhaust to reduce decibel levels in the operang environ-
ment.
If using a non-OEM silencer, it should be tested for eecveness by blanking o the
inlet and monitoring exhaust gas temperature with the blower running for at least
one hour. The blower should not exceed specied exhaust gas temperatures.
Tunable Ballast Silencer (4310 Blower)
A tunable ballast silencer provides for eld tuning of the ballast circuit to minimize the
noise for customer specic operang points.
If using a non-OEM silencer, it should be tested for eecveness in the same fashion
as described above for exhaust silencers.
Inlet Filter
The intake lters are designed to ensure maximum airow eciency why keeping out
unwanted debris. The lters supplied by NVE use a stainless steel screen and can be
cleaned.
Four Way Valve and Hoses
If it is intended to operate the blower in the pressure mode, a four way valve will be
required. The 4-way valve size should match the hose size used in the applicaon.
nvesalesrep.com | 888.814.9191