24 | 4307 & 4310 Blower
Clean Out Procedure if Flooded
1. Remove the inlet lter, exhaust silencer and ballast silencer.
2. With high pressure water, clean intake, exhaust and ballast areas.
3. Have an assistant slowly turn the input sha as you clean the lobes with water.
4. Run the blower at the lowest speed possible and connue to spray water into the
inlet of the machine unl the discharge shows only clean water.
5. With the blower running, spray a small amount of penetrang oil into the intake and
run unl no liquid comes out the exhaust. DO NOT SPRAY OIL INTO THE BLOWER
WITH THE SILENCERS IN PLACE.
6. Disassemble and clean the manifold/4-way valve assembly. Allow to dry then reas-
semble.
7. If the blower was ooded, it is highly probable the exhaust silencer has material in it
as well. Clean it out as best you can. Drain all uids from the silencer and allow it to
dry.
8. When everything is clean and dry, reassemble the manifold and
silencers. Make sure ange bolts on the blower are ghtened evenly.
OIL FILL
OIL DRAIN
OIL LEVEL
WITH BLOWER
SHUT DOWN
OIL LEVEL
SIGHT EYES
CHANGE OIL IN BOTH DRIVE AND NON-DRIVE OIL TANKS
DRIVE
END
NON-DRIVE
END
NonDriveSide
Oz(Liters)
Total
Size
BlowerOilCapacityDONOTOVERFILL
18(.53) 8(.24) 26(.77)
Size Capacity(oz) Manufacturer Grade
500Series 28 Summit SummitSyngearSH7220
600Series
8090 Mobil MonilubeSHC75W90
RightAngleGearboxLubricant
nvesalesrep.com | 888.814.9191