Do you have a question about the Observator OMC-160-3 and is the answer not in the manual?
| Brand | Observator |
|---|---|
| Model | OMC-160-3 |
| Category | Measuring Instruments |
| Language | English |
Crucial safety information regarding installation, moving parts, and working at heights.
Describes the OMC-160-3 as a combined wind speed and direction meter with specific features.
Details the primary components of the OMC-160 anemometer, including the sensor body and mounting bracket.
Identifies the cup unit and vane unit as the only moving parts of the anemometer.
Explains that the OMC-160 is a cup and vane anemometer, common in meteorological services.
States the anemometer is built for all weather conditions and is insensitive to noise, extreme temperatures, etc.
Lists the items included in the OMC-160 anemometer package upon delivery.
Provides guidance on selecting an optimal, turbulence-free location for mounting the anemometer.
Details requirements for mounting the bracket on a vertical pipe, including diameter and free space.
Describes the process of connecting the mounting clamp to the mast and securing it.
Explains how to attach the wind vane and cup unit to the sensor shafts using specific sequences.
Details the wiring and terminal functions for connecting the OMC-160 anemometer to power and signal cables.
Explains the meaning of the upper LEDs on the junction box PCB for wind direction alignment.
Describes the function of the lower LEDs on the junction box PCB for indicating sensor status.
Outlines the steps for powering, connecting, and verifying the OMC-160 anemometer's installation.
Provides a step-by-step guide for aligning the wind vane to North or the bow for accurate readings.
Defines the recommended intervals and tasks for routine preventive maintenance of the anemometer.
Provides instructions for safely disconnecting and removing the anemometer from its mounting.
Explains the calibration interval and services available for ensuring sensor accuracy.
Details the procedures and precautions for opening the anemometer for maintenance.
Provides detailed steps for replacing worn ball bearings and sensor PCBs within the anemometer.
States that the OMC-160-3 output is NMEA-0183 according to IEC 61162-1.
Specifies the default and configurable baud rates for the anemometer's data output.
Lists and explains the NMEA-0183 messages ($WIMWV, $WIVER) generated by the OMC-160-3.
Provides a comprehensive table of technical specifications for the OMC-160 anemometer.
Instructions for safely handling the instrument during unpacking and before installation.
Guidance on storing the OMC-160 anemometer in a dry place when not in use.
Procedures for shipping the anemometer for calibration or repair, including packaging advice.