    Kimberly GonzalesAug 15, 2025
    Why does the Oceanic OCS90 temperature window display '--Lo' or '--Ho'?
    • D
      Daniel LeonardAug 15, 2025
      The temperature window on your Oceanic Heater might display '--Lo' or '--Ho' due to several reasons: * If it displays '--Lo,' it could mean the temperature sensor isn't connected, the cable is broken, or the temperature is below 0°C. Check the connection and cable, or consider changing the sensor. * If it displays '--Ho,' it indicates a short circuit in the temperature sensor or that the temperature exceeds 115°C. Inspect the connection and cable, or replace the sensor. In some cases, you might need to change the controller.
  • A
    Amy JohnsonAug 18, 2025
    What to do if the OverHeat LED is on in my Oceanic OCS90 Heater?
    • J
      Jennifer GuerreroAug 18, 2025
      If the OverHeat LED is illuminated on your Oceanic Heater, it indicates a potential issue with the temperature sensor connection or the high-temperature cut-off switch. First, check the connection to the temperature sensor to ensure it is properly connected. Next, verify if the high-temperature cut-off switch is turned off; if it is, manually reset it.
  • S
    scott48Aug 21, 2025
    What to do if the Oceanic sauna heater controller is on but the sauna heater doesn’t work?
    • D
      David GomezAug 21, 2025
      If the controller of your Oceanic sauna heater is on, but the heater isn't working, there could be a connection problem or an issue with the controller itself. First, check the heater's connection. If the connection is correct, you may need to replace the controller.
  • S
    Sean MaxwellAug 25, 2025
    What to do if the Oceanic OCS90 'Wait' LED is red?
    • C
      Courtney JeffersonAug 25, 2025
      If the 'Wait' LED on your Oceanic Heater is red, it means the sauna heater is in B mode. To resolve this, press the Mode button to switch to A mode, which is the heating mode.
  • E
    Emily JohnsonAug 27, 2025
    How to fix Oceanic OCS90 Heater when there is no display on the control panel?
    • N
      Nicole GravesAug 27, 2025
      If there is no display on the control panel of your Oceanic Heater when you press the on/off switch, the issue might be with the power supply, the circuit board transformer, or the fuse. Begin by checking the power supply. If the power supply indicator LED L1 (red) is on, inspect the wire. If the power supply is not the issue, consider changing the controller.
  • V
    vjohnsonAug 30, 2025
    What to do if Oceanic Heater temperature windows display --L or --H?
    • M
      Mathew MartinezAug 30, 2025
      If the temperature windows display '--L' or '--H' on your Oceanic Heater, it indicates a problem with the thermometer or the temperature being outside the measurable range. Specifically: * '--L' means the temperature sensor isn't connected, the cable is broken, or the temperature is below 0°C (32°F). Check the connection and cable, or replace the sensor. * '--H' indicates a short circuit in the temperature sensor or the temperature exceeding 115°C (239°F). Again, inspect the connection and cable, or replace the sensor. If the issue persists, consider changing the controller.
  • Q
    qjacksonSep 2, 2025
    Why is the High1 LED on my Oceanic OCS90 Heater?
    • A
      angelriveraSep 2, 2025
      If the 'High1' LED is illuminated on your Oceanic Heater, it means that either the temperature sensor isn't properly connected or the high-temperature cut-off switch has been activated. First, check the connection to the temperature sensor. If that's not the issue, verify if the high-temperature cut-off switch is turned off; if it is, manually reset it.
  • K
    Kenneth AriasSep 5, 2025
    What to do if Oceanic OCS90 Heater controller is on but the sauna heater doesn’t work?
    • M
      michael45Sep 5, 2025
      If your Oceanic sauna heater controller is on, but the heater isn't working, it could be due to a couple of reasons. First, ensure that the sauna heater is properly connected, referring to the diagrams in figures 2 and 10. If the connection is correct and the heater still doesn't work, the controller might be faulty, and you may need to replace it.
  • J
    Jordan MckaySep 8, 2025
    How to troubleshoot no display on Oceanic OCS90 control panel?
    • D
      Deanna FernandezSep 8, 2025
      If there is no display on the control panel of your Oceanic Heater when you press the on/off switch, it indicates a problem with the power supply, the circuit board transformer, or the fuse. Check the power supply first. If the power supply indicator LED L1 (red) is lit, then check the wire. If not, consider changing the controller.
  • C
    Charles BlairSep 12, 2025
    Why is the Wait LED on on my Oceanic OCS90 Heater and how to fix it?
    • L
      lori55Sep 12, 2025
      If the 'Wait' LED is illuminated on your Oceanic Heater, it signifies that the sauna heater is operating under the B model setting. To resolve this, simply press the Model button to switch to the A model, which is the heating mode.

Summary

SAUNA HEATER with OCSB;LB CONTROLLER Assembly and operating manual

3. Safety Precautions

4. Electrical connection

4.1. Installation overview

Provides a general overview of the electrical installation process for the sauna heater.

4.2. Circuit Diagram

Presents technical diagrams detailing the electrical connections and circuit layouts for the system.

5. Sauna Heater Parameters

7. Installation

7.1. Minimum Clearances

Specifies the required minimum distances for safe and correct installation of the heater and controller.

7.2. Installation for sauna heater

Step-by-step instructions for mounting and wiring the sauna heater unit to the wall.

7.3. Installation for controller

Guidance on the optimal placement and installation method for the control box.

7.4. Installing the temperature sensor

Instructions for correctly positioning and securely fixing the temperature sensor in the sauna room.

8. Sauna heater, controller and temperature sensor connection drawing

9. Testing and Operation

10. Trouble shooting Guide

11. Maintenance

Oceanic OCS90 Specifications

General IconGeneral
BrandOceanic
ModelOCS90
CategoryHeater
LanguageEnglish

Related product manuals