EasyManua.ls Logo

OHAUS CD-11 User Manual

OHAUS CD-11
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PAGE 1 OF 30 0908 IH-606
H-606
1
Ohaus CorporationOhaus Corporation
Ohaus CorporationOhaus Corporation
Ohaus Corporation
29 Hanover Road
Florham Park, NJ
07932-0900
INSTRUCTION MANUAL
Model CD-11 Indicator
2
IEC1010-1 & EN60950:1992 Safety Regulations
IEC1010-1 & EN60950:1992 Sicherheitsbestimmungen
IEC1010-1 & EN60950:1992 Consignes de sécurité
IEC1010-1 & EN60950:1992 Disposiciones sobre seguridad
IEC1010-1 & EN60950:1992 Prescrizioni . di sicurezza
EN55022:1987 Emissions
EN50082-1:1992 Immunity
NOTE: The displayed value may be adversely affected under
extreme electromagnetic influences, eg. when using a radio unit in the
immediate vicinity of the device. Once the interference has been
rectified, the product can once again be used for its intended purpose.
EN55022:1987 Funkstörungen
EN50082-1:1992 Immunität
Hinweis: Unter extremen elektromagnetischen Einflüssen z.B. bei
Betreiben eines Funkgerätes in unmittelbarer Nähe des Gerätes kann
eine Beeinflussung des Anzeigewertes verusacht werden. Nach Ende
des Störeinflusses ist das Produkt wieder bestimmungsgemäss
benutzbar.
EN55022:Emissions parasites
EN50082-1:1992 Immunité
Remarque: Dans des conditions d'influences électromagnètiques
extrêmes, par exemple en cas d'exploitation d'un appareil radio à
proximité immédiate de l'appareil la valeur d'affichage risque d'être
influencée. Une fois que l'influence parasite est terminée, le produit
peut être de nouveau utilisé de manière conforme aux prescriptions.
EN55022:1987 Radiointerferencias
EN50082-1:1992 Inmunidad
Nota: Bajo influencias electromagnèticas extremas, p.ej. cuando
funciona una radio en las inmediaciones del aparato, se pueden
alterar los valores del display. Cuando concluye el efecto perturbador,
el producto puede ser utilizado de nuevo, de acuerdo con lo
estipulado.
EN55022:1987 Radiointerferenze
EN50082-1:1992 Immunità
Nota: ll valore visualizzato può essere influenzato negativamente dalla
presenza di forti interferenze elettromagnetiche, per esempio quando
viene usata una radio in prossimità della bilancia. Eliminata la fonte
dell'interferenza, il prodotto può essere nuovamente utilizzato per le
funzioni cui è preposto.
EU 73/23 Low Voltage
EU 73/23 Niederspannung
EU 73/23 Basse tension
EU 73/23 Baja tensión
EU 73/23 Bassa tensione
EU 89/336, 92/31, 93/68
Electromagnetic compatibility
EU 89/336, 92/31, 93/68
Elektromagnetische Verträglichkeit
EU 89/336, 92/31, 93/68
Compatibilité électromagnétique
EU 89/336, 92/31, 93/68
Compatibilidad electromagnética
EU 89/336, 92/31, 93/68
Compatibilità elettromagnetica
Ohaus Corporation, 29 Hanover Road, Florham Park, New Jersey, 07932, USA
Declaration of Conformity We, Ohaus Corporation, declare under our sole responsibility that the instrument models listed below marked with
CE - are in conformity with the directives and standards mentioned.
Konformitätserkärung Wir, die Ohaus Corporation, erklären in alleiniger Verantwortung, dass die untenstehenden Waagentypen, instrument
mit “CE” - mit den genannten Richtlinien und Normen übereinstimmen.
Déclaration de conformité Nous, Ohaus Corporation, déclarons sous notre seule responsabilité, que les types de instrument ci-dessous cité
- munis de la mention «CE» - sont conformes aux directives et aux normes mentionnées ci-après.
Declaración de Conformidad Nosotros, Ohaus Corporation, declaramos bajo responsabilidad exclusiva que los modelos de instrumento
indicados a continuación - con el distintivo ,CE’ - están conformes con las directivas y normas citadas.
Dichiarazione di conformità Noi, Ohaus Corporation, U.S.A, dichiariamo sotto nostra unica responsabilità, che i tipi di strumento specificati di
seguito - contrassegnati con la marcatura CE - sono conformi alle direttive e norme citate.
Instrument Type/Waagentyp/Type de instrument/Modelo de instrumento/Tipo di strumento CD-11 Indicator
Marked with: Directive Standard
Gekennzeichnet mit: Richtlinie Norm
Munis de la mention: Directive Norme
Con el distintivo: Directiva Norma
Contrassegnati con la Direttiva Norma
Marcatura:
H-606 Deluxe Bench Scale

Questions and Answers:

OHAUS CD-11 Specifications

General IconGeneral
BrandOHAUS
ModelCD-11
CategoryScales
LanguageEnglish

Summary

Overview of Controls and Indicator Functions

Getting to Know Your Indicator

Introduction

Overview of the CD-11 Indicator, its features, and capabilities.

Installation

Unpacking and Checking

Instructions for unpacking and verifying the included accessories.

Selecting the Location

Guidelines for choosing an optimal operating environment for the indicator.

Connecting the Indicator to a Scale Base

Procedure for physically connecting the scale base load cell cable to the indicator.

Cautionary Notes

Important warnings and precautions for the safe operation of the indicator.

Connecting Power

Details on powering the indicator via AC adapter or batteries.

Setup Protection

Information on using the menu lockout feature to prevent unauthorized setting changes.

Initial Setup

Control Functions

Details on the buttons used for navigating and changing settings during initial setup.

Menu Structure

Diagram illustrating the hierarchy and flow of the indicator's setup menus.

Load Cell Capacity Information

Table to determine compatible indicator settings based on scale base capacity and resolution.

Setup Menu

Procedure for setting scale base parameters like Legal for Trade, zero range, calibration unit, capacity, and graduation.

Readout Menu

Configuration of environmental adaptations, unit display, auto-zero tracking, and timers.

Print Menu

Settings for data communication, including baud rate, parity, data length, and stop bits.

Lockout Switch Menu

Controlling access to Calibration, Setup, Readout, and Print menus to prevent unauthorized changes.

Connecting the RS232 Interface

Details on the RS232 connector pinout and its use for data communication.

Calibration and Sealing

Legal for Trade (LFT) Operation and LFT Sealing

Steps for configuring and sealing the indicator for legal for trade use, including jumper settings and seals.

Operation

Turning On Indicator

Procedure for powering the indicator on and its initial self-test sequence.

Turning Off Indicator

Instructions on how to properly shut down the indicator.

Zero Operation

Steps to zero the indicator, ensuring it registers zero weight before adding a load.

Tare Operation

Method for taring the weight of a container to accurately measure the net weight of contents.

Gross/Net/Tare Recall Operation

How to cycle through and display Gross, Net, and Tare weight values.

Clear Tare Operation

Procedure to remove a stored tare weight from the indicator's memory.

Unit Switch Operation

How to change the displayed unit of measurement (e.g., lb, kg, g) using the Print/Units button.

Parts Counting Operation

Enabling and using the parts counting function based on average piece weight.

Establishing a New Average Piece Weight (APW)

Guide to setting up a new average piece weight for accurate parts counting.

Returning to a Weighing Mode

How to exit specific modes and return the indicator to its standard weighing display.

Returning to a Preset APW

Using a previously calculated Average Piece Weight for parts counting.

RS232 Commands

List and explanation of ASCII commands for communication with external devices.

Printing Data

Instructions for printing data to an external computer or printer.

Care and Maintenance

Troubleshooting

Common problems, their probable causes, and suggested remedies for the indicator.

Error Codes List

Explanation of various error codes displayed by the indicator and their recommended solutions.

Service Information

Contact information and procedures for obtaining service assistance for the indicator.

Replacement Parts

List of available replacement parts for the indicator, including part numbers.

Accessories

List of optional accessories that can be purchased for the indicator.

Technical Data

Detailed specifications including capacity, resolution, functions, power, dimensions, and weight.

Related product manuals