What to do if OHAUS Measuring Instruments shows “Close Cover”?
- BbarbarasilvaAug 17, 2025
If the OHAUS Measuring Instrument displays “Close Cover”, it means the cover needs to be closed before starting the test. Please close the cover to proceed.
What to do if OHAUS Measuring Instruments shows “Close Cover”?
If the OHAUS Measuring Instrument displays “Close Cover”, it means the cover needs to be closed before starting the test. Please close the cover to proceed.
What to do if OHAUS Measuring Instruments shows “Tare”?
If the OHAUS Measuring Instrument shows “Tare”, it indicates that the pan weight needs to be set to zero. Press the Tare button to zero the pan weight.
Why is the weight value blinking on my OHAUS Measuring Instruments?
If the OHAUS Measuring Instrument displays a blinking weight value, it means the sample weight is less than 0.5g. Increase the sample size to resolve this issue.
What does Err 8.3 mean on OHAUS Measuring Instruments?
If the OHAUS Measuring Instrument shows Err 8.3, it means the weight on the pan support exceeds capacity. Remove weight from the pan support.
What does Err 8.1 mean on OHAUS Measuring Instruments?
If the OHAUS Measuring Instrument shows Err 8.1, it indicates that the pan support has a load during power on. Remove any weight from the pan support.
What does Err 8.5 mean on OHAUS Measuring Instruments?
If the OHAUS Measuring Instrument displays Err 8.5, it means the analyzer temperature is above 50°C. Cool down the analyzer.
What does Err 8.6 mean on OHAUS Measuring Instruments?
If the OHAUS Measuring Instrument shows Err 8.6, it means the analyzer temperature is higher than the target setting. Cool down the analyzer.
How to improve accuracy of OHAUS Measuring Instruments?
If you are experiencing poor accuracy with your OHAUS Measuring Instrument, perform a calibration. Also, move the analyzer to a more stable location.
What does Err 8.4 mean on OHAUS Measuring Instruments?
If the OHAUS Measuring Instrument shows Err 8.4, it indicates that the pan support was removed during weighing. Re-install the pan support.
What does Err 8.2 mean on OHAUS Measuring Instruments?
If the OHAUS Measuring Instrument shows Err 8.2, it means the pan support was removed prior to power on. Install the pan support.
Capacity | 110 g |
---|---|
Readability | 0.01 g |
Heating Element | Halogen |
Pan Size | 90 mm |
Display | LCD |
Calibration | External Calibration |
Interface | RS232 |
Repeatability (Std. Dev.) | 0.01 g |
Operating Temperature Range | 10 °C to 40 °C |
Power Supply | AC 100-240 V |
General safety guidelines, heat handling, and special sample precautions.
OHAUS disclaimer on application data validation and liability.
List of all items included with the MB23/MB25 moisture analyzer.
Guidelines for selecting a suitable location and installing components.
Instructions for safely connecting the analyzer to the AC power supply.
Overview of the analyzer's display indicators and control buttons.
Explanation of Standby Mode and Weigh Mode operations.
Setting drying temperature, time, and preparing the sample for a test.
Steps for running a test, viewing results, and exiting modes.
Guidance on trial runs and optimizing drying temperature, time, and sample weight.
Importance of uniform and thin sample distribution on the test pan.
Advice for testing various sample types, including volatile and corrosive substances.
Instructions for weight and temperature calibration of the analyzer.
Procedures for cleaning the analyzer and resolving common operational issues.
List of optional accessories available for the moisture analyzer.
Admissible ambient conditions and detailed technical specifications of the analyzer.
Pin connections, data settings, and commands for RS232 interface.
Comprehensive list of RS232 commands and examples of data output.
Product compliance with various safety and regulatory standards.
Guidelines for proper disposal of electronic equipment according to WEEE directive.
Compliance statements for FCC and Canadian digital apparatus.
Details Ohaus Corporation's ISO 9001 certification status.