Do you have a question about the OHAUS STARTER 3100M and is the answer not in the manual?
Model | Starter 3100M |
---|---|
Readability | 0.01 pH |
Resolution (pH) | 0.01 pH |
Accuracy (pH) | ±0.01 pH |
Calibration | Automatic |
Calibration Points | Up to 5 points |
Display | LCD |
Units of Measurement | pH |
Housing Material | Plastic |
Operating Temperature | 0 to 50 °C |
Type | pH Meter |
Relative Humidity | 80% RH (non-condensing) |
Explains safety symbols and signal words used to indicate hazards and precautions.
Provides critical safety guidelines for operating and maintaining the instrument.
Details the meter's display layout, icons, symbols, and button functions for operation.
Lists all items included in the STARTER 3100M multi-parameter bench meter package.
Provides instructions on how to assemble and install the electrode holder arm on the meter base.
Details the procedure for connecting the power adapter to the meter.
Explains how to connect pH, temperature, and conductivity electrodes to the meter.
Describes the function of the meter stand for optimal display viewing angle.
Mentions the presence of an attached quick guide for user assistance.
Covers initial configuration settings for pH measurement operations.
Guides on setting temperature units (C/F) and Manual Temperature Compensation (MTC).
Explains how to choose a buffer group for pH calibration based on standards.
Outlines the process and methods for calibrating the pH electrode.
Details the steps for conducting a single-point pH calibration.
Provides instructions for performing a two-point pH calibration.
Covers procedures for taking pH and mV measurements.
Step-by-step guide for performing a pH measurement.
Instructions for performing millivolt (mV) measurements.
Details the setup procedures for conductivity measurements.
Guides on setting temperature units (C/F) for conductivity measurements.
Explains how to set the Manual Temperature Compensation (MTC) for conductivity.
Describes how to select the standard points for conductivity calibration.
Details setting the temperature correction coefficient for conductivity.
Guides on setting the TDS conversion factor for measurements.
Outlines the process for calibrating the conductivity electrode.
Explains how to choose the calibration standard for conductivity.
Provides instructions for performing a conductivity calibration.
Covers procedures for taking conductivity, TDS, Salinity, and Resistivity measurements.
Step-by-step guide for performing a conductivity measurement.
Instructions for performing TDS, Salinity, and Resistivity measurements.
Details how to store pH and conductivity measurement results in the meter's memory.
Explains how to retrieve stored measurement data from the meter.
Guides on how to delete stored data from the meter's memory.
Lists common error codes in pH and conductivity modes and their solutions.
Provides general maintenance advice for the instrument, excluding electrodes.
Describes how to perform a self-diagnosis check on the meter's functions.
Guides on resetting the meter to its original factory default settings.
Lists the technical specifications, ranges, resolutions, and accuracies of the meter.
Details regulatory compliance, WEEE disposal, and FCC notes for the device.
Lists temperature-dependent pH values for various buffer groups used in calibration.
Provides conductivity values for calibration standards at different temperatures.
Shows temperature coefficients for conductivity calculations and standards.
Lists conversion factors for calculating TDS from conductivity measurements.