Do you have a question about the OHAUS MB45 and is the answer not in the manual?
Maximum Capacity | 45 g |
---|---|
Readability | 0.001 g / 0.01% |
Heating Technology | Halogen |
Pan Size | 90 mm |
Temperature Increments | 1°C |
Calibration | External calibration |
Operating Temperature Range | 10°C to 40°C |
Interface | RS232 |
Temperature Range | 50°C to 200°C |
Display | LCD |
Moisture Range | 0% to 100% |
Repeatability (Std. Dev.) | 0.015% (10g sample) |
Power | 50/60 Hz |
Details the MB45 model, EC directives, additional standards, and ISO 9001 certification.
Introduces the MB45 Moisture Analyzer and its features.
Explains the thermogravimetric principle of operation.
Essential safety guidelines for operation, including heat and hazardous substance handling.
Explains manual structure and graphic symbols for guidance.
Details the function of each button and indicator on the analyzer's front panel.
Instructions for unpacking and verifying all accessories are present.
Guidance on choosing an appropriate location, avoiding environmental factors.
Steps for installing heat shield, draft shield, and pan support.
Procedures for leveling the instrument and connecting to a power supply.
Instructions on switching the analyzer on/off and warm-up procedures.
Step-by-step guide for performing an initial measurement using factory defaults.
How to view and interpret displays showing drying and measurement progress.
Describes the Setup and Test menus and their primary functions.
Explains navigation, option selection, and data entry using analyzer buttons.
Enables lockout to prevent accidental changes to analyzer settings.
Procedure for calibrating the balance using a 20-gram mass.
Steps for calibrating dryer unit temperature at two points.
Select display language and adjust audible signal level.
Setting the instrument's current time, date, and format.
Configuring baud rate, parity, data bits, stop bits, and handshake for RS232.
Enabling print output and Good Laboratory Practice (GLP) data formatting.
Adjusting contrast and brightness levels of the analyzer's display.
Procedure for resetting the analyzer to its original factory default settings.
Explains fundamental principles of operating the analyzer for precise measurements.
Assigning a unique identifier (Test ID) to a measurement for tracking.
Configuring drying profile, temperature, switch-off criteria, and result display.
Setting sample weight and print frequency for automatic data printing.
Saving, exiting, running tests, and displaying run data and statistics.
Describes library capacity and how to store, recall, and edit tests.
Procedures for modifying or removing tests from the library.
Explains thermogravimetric method and crucial sample preparation factors.
Guidance on selecting optimal drying temperature, programs, time, and switch-off criteria.
Interpreting drying curves and optimizing results based on decomposition and asymptotic profiles.
Examples of printouts and RS232 commands/pinout for data output.
Instructions for cleaning instrument components, including sensor and glass.
Procedure for replacing a fuse and diagnosing common operational problems.
Understanding error signals, contacting service, and listing optional accessories.
Technical specifications including capacity, readability, dimensions, and operating conditions.
Recommended settings for various sample types and related preparation/drying notes.
Details warranty coverage, exclusions, and procedures for repair or replacement.