What does 'Err13 mMEmM' mean on OHAUS Scales?
- PPaige MooreSep 7, 2025
If your OHAUS scale shows 'Err13 mMEmM', it means there was a failure to write to the EEPROM. Contact an authorized service agent.
What does 'Err13 mMEmM' mean on OHAUS Scales?
If your OHAUS scale shows 'Err13 mMEmM', it means there was a failure to write to the EEPROM. Contact an authorized service agent.
Why OHAUS Scales cannot turn on?
If your OHAUS scale isn't turning on, the issue is likely due to a lack of power. Verify the connections and the power source to ensure the scale is receiving power.
Why OHAUS Valor 2000W Scales cannot calibrate?
If you cannot calibrate your OHAUS Scales, it might be caused by an unstable environment or using an incorrect calibration weight. Move the scale to a suitable location and ensure you are using the correct calibration weight.
Why OHAUS Scales show 'Poor accuracy'?
Poor accuracy in OHAUS Scales can stem from a couple of things. First, the scale might not be calibrated correctly; in this case, you should perform calibration. Second, the surrounding environment might be unstable. If that's the case, relocate the scale to a more stable location.
What to do if OHAUS Valor 2000W display 'Lo.Bat'?
If your OHAUS scale displays 'Lo.Bat', it means the battery is discharged. To resolve this, connect the power and charge the battery.
What to do if OHAUS Scales display 'Err 8.3 ¯LOad¯'?
If your OHAUS scale shows 'Err 8.3 ¯LOad¯', it indicates an overload. This means the load on the scale exceeds its maximum capacity.
What does Err 8.5 ?tare? mean on OHAUS Scales?
If your OHAUS Scales display 'Err 8.5 ?tare?', the tare value exceeds the maximum.
What does 'Err 53 C.SUmM' mean on OHAUS Valor 2000W?
If your OHAUS scale displays 'Err 53 C.SUmM', it indicates invalid checksum data. Contact an authorized service agent to address this issue.
What to do if OHAUS Valor 2000W Scales display 'Err 9 Data'?
If your OHAUS scale is displaying 'Err 9 Data', it indicates an internal data error. Contact an authorized service agent to resolve this.
What does 'Err 3.0 Cal' mean on OHAUS Valor 2000W Scales?
If your OHAUS scale is showing 'Err 3.0 Cal', it means that the calibration weight used was incorrect. Refer to table 3-4 for the correct weights.
Essential safety measures to follow before and during operation of the scale.
List of items included in the product package.
Instructions for physically assembling the scale components, including the pan.
Guidelines for choosing an optimal and stable environment for scale operation.
Procedure for ensuring the scale is perfectly level using adjustable feet.
Details on connecting and using AC adapter and battery power sources.
Identification and function of buttons on the Valor 2000W V22PW front control panel.
Steps to power the scale on and off safely.
Accessing and navigating the calibration menu for span and GEO settings.
Step-by-step guide for performing the initial calibration of the scale.
Procedure to access and change the displayed weighing units on the scale.
Identification and function of buttons on the Valor 2000W V22XW front control panel.
Instructions for powering the scale on and off.
Procedure for calibrating the scale upon initial installation.
How to use the scale for standard weighing operations.
Setting up and using the checkweighing function with limit indicators.
Customizing scale settings through various menus.
Proper methods for cleaning the scale housing and control panels.
Instructions for removing, cleaning, and reinstalling the plastic pan.
Common issues, their causes, and recommended solutions for scale operation.
Contact information and procedures for obtaining technical support and service.
Detailed technical specifications including capacity, readability, and dimensions.
Diagrams illustrating scale dimensions and measurements.
Information regarding product compliance with various industry standards and regulations.