INTRODUCTION
TECHNICAL SPECIFICATIONS
CONTROL ELEMENTS
ASSEMBLY & PREPARATION
OPERATING MODES
DATA TRANSFER
OKM ROVER C4
MANUAL
Question and Answer IconNeed help?

Do you have a question about the OKM ROVER C4 and is the answer not in the manual?

Summary

Introduction to OKM Rover C4

Preface

An introductory statement from OKM GmbH thanking the customer for their purchase of the Rover C4.

Important Notes

Crucial safety and operational guidelines for using the Rover C4 and its accessories.

Maintenance and Services

Instructions on how to maintain the measuring instrument and accessories for optimal condition and results.

Danger of Explosion During Excavation

Warning about potential explosive relics in the ground and safe handling procedures.

Care and Use

Do's and Don'ts for the proper care and usage of the Rover C4 to prevent damage.

Protecting Your Investment

Guidelines to maintain the detector's performance and prevent degradation over time.

Technical Specifications

Control Unit Specifications

Detailed technical specifications for the Rover C4 control unit, including dimensions and components.

Wireless Data Transfer Specifications

Technical specifications related to the wireless data transfer capabilities of the device.

Standard Probe Specifications

Technical specifications for the Standard Probe accessory.

Super Sensor Specifications

Technical specifications for the Super Sensor accessory.

Control Elements

Control Unit Components

Detailed explanation of the Rover C4's control unit components and their functions.

Standard Probe and Super Sensor

Description of the Standard Probe and Super Sensor, including their LED Orbit feature.

Bluetooth Headphones Usage

Information on connecting and using Bluetooth headphones with the Rover C4.

Assembly and Preparation

Pairing Bluetooth

Step-by-step guide to pairing the OKM detector with a computer via Bluetooth.

Assembling the Detector

Instructions on how to assemble the Rover C4 detector and prepare it for measurement.

Operating Modes

3 D Ground Scan Overview

Guide to performing a graphical 3D measurement for detailed analysis on a computer.

Preparing a 3 D Ground Scan

Details on adjusting essential parameters before conducting a 3D Ground Scan.

Saving Scan Data into Memory

Instructions for saving scan data into one of the four memory areas.

Transferring Scan Data to Computer

Steps for establishing a wireless data connection for real-time transfer to a PC.

Conducting a 3 D Ground Scan

Step-by-step guide on how to perform the actual 3D ground scan measurement.

Pinpointer Mode Overview

How to use the Pinpointer mode for precise target location and metal differentiation.

Preparing a Pinpointer Scan

Steps to prepare for a Pinpointer scan, including data transfer setup.

Conducting a Pinpointer Scan

Instructions on how to perform the actual measurement in Pinpointer mode.

Analyzing a Pinpointer Scan

Guidance on interpreting signatures in Pinpointer mode to identify target characteristics.

Magnetometer Mode Overview

Information on using the Magnetometer mode for detecting ferromagnetic metals.

Preparing a Magnetometer Scan

Steps to prepare for a Magnetometer scan, including ground balance.

Conducting a Magnetometer Scan

How to perform the actual measurement using the Magnetometer mode.

Mineral Scan Overview

Guide to prospecting for mineral deposits and natural gold using the Mineral Scan mode.

Preparing a Mineral Scan

Steps for preparing a Mineral Scan, including memory selection.

Conducting a Mineral Scan

Instructions on how to perform the actual measurement in Mineral Scan mode.

Analyzing a Mineral Scan

Guidance on analyzing scan data from Mineral Scan mode using Visualizer 3D Studio.

Memory to PC Data Transfer

How to transfer measured data from the Rover C4 internal memory to the PC software.

Device Settings Menu

How to adjust various device settings like volume, language, and lighting.

Adjusting Volume

Adjusting the volume for internal speakers or connected Bluetooth headphones.

Connecting Bluetooth Headphones

Steps to connect Bluetooth headphones to the Rover C4.

Changing Language

How to change the user interface language of the Rover C4.

Controlling Lighting

Toggling the LED lights for illumination during scanning.

Adjusting Display Brightness

Regulating the display and touchscreen brightness for optimal visibility.

Factory Reset

Resetting all configurations to factory defaults.

Device Information

Displaying device serial number and firmware version for support.

Preparing Data Transfer

Data Transfer Setup Steps

Steps to initiate and configure data transfer to the Visualizer 3D Studio software.

OKM ROVER C4 Specifications

General IconGeneral
Detection DepthUp to 25 meters
Max Depth25 meters
DisplayLCD
Data TransmissionBluetooth
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
WaterproofNo
Data StorageInternal memory
Frequency12.5 kHz
Operating ModesMagnetometer, Pinpointer
Power SupplyRechargeable battery
Operating Frequency12.5 kHz