OLC(T) 100
User manual
Calibration coefficients of explosive gases for catalytic detectors
When a VQ1 type sensor is used (available for OLC 100 and OLCT 100), the
coefficients are as follows:
Gas
Chemical
Formula
LEL
(%)
LSE
(%)
Flash
point (°C)
Vapor
density
Coefficient
-
Calibration gas
CH4 (methane)
Coefficient
-
Calibration gas
H2 (Hydrogen)
Coefficient
-
Calibration gas
C4H10 (Butane)
Coefficient
-
Calibration gas
C5H12 (Pentane)
Ethyl acetate
C4H8O2
2.10
11.50
-4
3.0
1.65
0.90
0.80
Acetone
C3H6O
2.15
13.00
-18
2.1
1.65
0.90
0.80
Acetylene
C2H2
2.30
100
-18
0.9
2.35
1.90
1.25
1.15
Acrylic acid
C3H4O2
2.40
8.00
54
2.5
5.00
2.65
2.40
Butyl acry late
C7H12O2
1.20
8.00
37
4.4
3.50
1.85
1.70
Ethyl acry late
C5H8O2
1.70
13.00
-2
3.5
3.05
1.65
1.50
Acrylonitrile
C3H3N
2.80
28.00
-1
1.8
1.45
1.20
0.80
0.70
Ammoniac
NH3
15.00
30.20
< -100
0.6
0.90
0.75
0.50
0.45
Benzene
C6H6
1.20
8.00
-11
2.7
4.00
2.15
1.90
1.3-Butadiene
C4H6
1.40
16.30
-85
1.9
2.55
1.35
1.25
Butane
C4H10
1.50
8.50
-60
2.0
1.90
1.00
0.90
Butanol (Buty l
Alcool)
C4H10O
1.4
11.3
29
2.6
1.95
1.05
0.95
2 - Butanone
(MEK)
C4H8O
1.80
11.50
-4
2.5
3.90
2.10
1.90
Cyclohexane
C6H12
1.20
8.30
-17
2.9
2.00
1.10
1.00
Dimethy lether
C2H6O
3.00
27.00
-41
1.6
1.80
0.95
0.90
Dodecane
C12H26
0.60
~6.0
74
5.9
4.00
2.15
1.90
Ethane
C2H6
3.00
15.50
135
1.0
1.50
0.80
0.75
Ethanol
C2H6O
3.30
19.00
13
1.6
2.15
1.75
1.15
1.05
Ether
(Diethy lether)
(C2H5)2O
1.70
36.00
-45
2.6
1.90
1.00
0.90
Ethylene
C2H4
2.70
34.00
- 135
1.0
1.65
1.35
0.90
0.80
LPG
Prop+But
1.65
~9.0
< -50
1.9
1.90
1.00
0.90
Diesel
Melange
0.60
~6.0
55
> 4
3.20
1.70
1.55
Natural Gas
CH4
5.00
15.00
-188
0.6
1.05
HFO-1234yf
6.2
12.3
1.35
0.75
Heptane
C7H16
1.10
6.70
-4
3.5
2.20
1.20
1.05
Hexane
C6H14
1.20
7.40
-23
3.0
2.10
1.15
1.00
Hydrogen
H2
4.00
75.60
-
0.069
1.00
Isobutane
C4H10
1.50
8.40
-83
2.0
1.50
0.80
0.75
Isobutene
C4H8
1.60
10.00
<-10
1.9
2.20
1.20
1.05

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oldham OLCT 100 XP and is the answer not in the manual?

Oldham OLCT 100 XP Specifications

General IconGeneral
BrandOldham
ModelOLCT 100 XP
CategoryGas Detectors
LanguageEnglish

Related product manuals