4.1.b-Cleaningthesuctionlter
To ensure the indoor air is ltered correctly and to guarantee that your air conditioner runs efciently, it is vital
to clean the air lters regularly (Fig.20).
After a certain amount of time this important maintenance operation must be carried out. It is indicated when
the Fi alarm message appears on the control panel display.
a. Switch off the conditioner and then remove the lters from the conditioner as indicated in gure 20.
b. Wash the lter with a water jet aimed at the side opposite the accumulation of dust.
c. If the dirt is particularly difcult to remove (such as grease or other types of deposit), rst immerge the
lter in a solution of water and a neutral detergent.
d. Shake off any water before reinserting the lter.
Provideforthelter(23)replacementifitisdamaged.
e. Make sure the lter (23) has dried completely.
f. Correctly reposition the lter (23) in its specic seat.
g. Suck possible uff from the grille (Fig. 21).
Donotusetheappliancewithoutthelter(23).
4.1.c - Recommendations for energy saving
Below nd simple recommendations for reducing consumption:
Always and constantly keep the lters clean (see maintenance and cleaning chapter).
Keep the doors and windows of the rooms to be climate controlled closed.
Do not let sun rays penetrate freely into the room (we recommend using curtains or lowering blinds or
closing the shutters).
Do not obstruct the air ow path (input and output) of the appliance; this, in addition to obtaining a non-op-
timal yield, also affects the correct operation of the appliance and the possibility of irreparable damages to
the appliance itself.
4.2 - MAINTENANCE
If you do not intend to use the appliance for a long period of time, work as follows:
a.
Activate the fan only mode for a few hours (approximately 1÷2 hours) to dry the interior of the appliance.
b. Stop the air conditioner and disconnect the power supply.
c. Clean the air lter.
d. Completely discharge condensation.
e. Remove the batteries from the remote control.
Checks before resuming use of the air conditioner:
a. Clean the lters after a long period of inactivity of the air conditioner.
b. Check that the air outlet or inlet are not obstructed (especially after a long period of inactivity of the air
conditioner).
4.2.a - Discharging condensation
When condensation in the lower tray reaches the predetermined level, the appliance emits beeps.
In this case:
a. Disconnect the plug from the power socket.
b. Carefully move the appliance in position suitable to unload water.
c. Remove the drain cap (24) and the rubber cap (24a) (Fig.22).
Makesureyoucorrectlytightenedthedraincap(24)
in order to avoid water leak.