50
ENGLISH
3
To set the parameters see the table below that summarises the parameters.
Example:
Press ey4
, to view USr on the display
Press ey6
, to view the rst parameter hrS (clock hour setting)
Press ey6
, to view the parameter value (e.g.: 10)
Press ey6
for three seconds, the parameter value ashes on the display
Press ey1
/ey2 to increase or reduce the parameter value displayed
Press ey6
, to conrm the set value, the display stops ashing
Press ey4
, to exit and view the parameter
Press ey1
or ey2 to change parameter and proceed as above to change other parameters
Press ey1
and ey2 simultaneously to quit the user menu
Parameter DISPLAY
MNEMONIC
MENU Range of
adMustment
Factory
setting
COMMENTS
SSTEM CLOC:
HOUR SETTING
hS User 0-23 0
SSTEM CLOC:
MINUTE SETTING
in User 0-59 0
TIMER ACTIVATION/
DEACTIVATION
0 timer deactivated
1 timer activated
ti User 0-1 0
SSTEM START TIME
StA User 00.0 – 23.5 0.00
Decimals tens of minutes,
e.g.: 0.110 minutes, 0.550
minutes
SSTEM SHUTDOWN
TIME Sto User 00.0 – 23.5 0.00
Decimals tens of minutes,
e.g.: 0.110 minutes, 0.550
minutes
NIGHT-TIME MODE
ACTIVATION/
DEACTIVATION
0 night-time mode
deactivated
1 night-time mode
activated
ncL User 0,1 0
The yield and the maximum
noise level are reduced
NIGHT-TIME MODE
SWITCH-ON TIME nSt User 00.0 – 23.5 0.00
Decimals tens of minutes,
e.g.: 0.110 minutes, 0.550
minutes
NIGHT-TIME MODE
SHUTDOWN TIME nSP User 00.0 – 23.5 0.00
Decimals tens of minutes,
e.g.: 0.110 minutes, 0.550
minutes
Inlet water temperature
t1
Temperature/
Set
Outlet water
temperature
t2
Temperature/
Set
Domestic water tank
sensor temperature
t3
Temperature/
Set
Outside air sensor
temperature
t4
Temperature/
Set
Compressor operating
hours CHC
Temperature/
Set
COOLING SET-POINT
1
cS1
Temperature/
Set
User
Luc0: 7°C
- 25°C
Luc1: 4°C
- 20°C
Luc0: 20°C
Luc1: 15°C
Factory settings for radiant
oors
COOLING SET-POINT
2 (Eco Mode)
cS2
Temperature/
Set
User
Luc0: 7°C
- 25°C
Luc1: 4°C
- 20°C
Luc0: 23°C
Luc1: 18°C
Factory settings for radiant
oors
HEATING SET-POINT
1
HS1
Temperature/
Set
User
Luc0: 20°C
- 55°C
Luc1: 20°C
- 60°C
Luc0: 30°C
Luc1: 35°C
Factory settings for radiant
oors

Table of Contents