The Olympus IPLEX FX series is an industrial videoscope designed for observing and examining the interiors of machinery, equipment, or buildings that cannot be directly viewed from the outside. It is not intended for use in human or animal body cavities. The series includes the base unit IV8000-2, which can be paired with various scope units (IV8420, IV8435, IV8620, IV8635, IV8650, IV8675, IV8635X1) and optical adapters.
Function Description
The IPLEX FX series allows for visual inspection and image recording (still and moving images with audio) of internal structures. It features angulation control for precise scope manipulation, zoom functionality for magnified views, and brightness adjustment for optimal image clarity. The device supports stereo measurement for 3D coordinate-based measurements and scaler measurement using a reference length. Recorded images can be replayed on the device or transferred to a computer for further analysis using the bundled IPLEX VIEWER PLUS software.
Important Technical Specifications
Scope Unit
- Channel Inner Diameter (IV8635X1): φ 1.6 mm
- Total Length:
- IV8420: 2 m
- IV8435: 3.5 m
- IV8620: 2 m
- IV8635: 3.5 m
- IV8650: 5 m
- IV8675: 7.5 m
- IV8635X1: 3.5 m
- Angulation: Power-assisted.
- IV8420, IV8435: 130°
- IV8620: 150°
- IV8635: 130°
- IV8650: 110°
- IV8675: 90°
- IV8635X1: 120°
- Angulation is in UP, DOWN, RIGHT, and LEFT directions. The insertion tube is straight.
- Flexible Section:
- IV84 series: Fixed hard tube from the distal end of the insertion tube to the control unit.
- IV86, IV8635X1 series: TF tube with flexibility gradually increasing toward the distal end.
- Outer Diameter:
- IV84 series: φ 4.0 mm
- IV86 series: φ 6.0 mm
- IV8635X1: φ 6.2 mm
- Index Lines:
- IV84, IV86 series: Orange line at 500 mm from distal end, white lines every 1000 mm (1 line at 1000 mm, 2 lines at 2000 mm).
- IV8635X1: Six white lines and five orange lines at 20 mm intervals from 300 mm, ten white lines at 20 mm intervals from 2350 mm.
Optical Adapter Specifications
- For 4-mm type scope unit:
- Outer Diameter: φ 4.0 mm
- Rigid Distal End Length: 19.6 mm to 28.8 mm (depending on model)
- Field of View: 50°/50° to 120°
- Direction of View: Forward, Side, Forward/Forward, Side/Side
- Depth of Field: 1 to 190 mm to 4 to ∞ mm (depending on model)
- For 6-mm type scope unit:
- Outer Diameter: φ 6.0 mm
- Rigid Distal End Length: 19.8 mm to 32.2 mm (depending on model)
- Field of View: 40° to 120°, 60°/60°
- Direction of View: Forward, Side, Forward/Forward, Side/Side
- Depth of Field: 4 to 190 mm to 200 to ∞ mm (depending on model)
- For 6.2-mm type (IV8635X1) scope unit:
- Outer Diameter: φ 6.2 mm
- Rigid Distal End Length: 20.5 mm to 32.9 mm (depending on model)
- Field of View: 80° to 120°, 60°/60°
- Direction of View: Forward, Side, Forward/Forward, Side/Side
- Depth of Field: 4 to 190 mm to 25 to ∞ mm (depending on model)
Base Unit
- Dimensions: 250 (W) x 160 (D) x 285 (H) mm
- Weight: 4.9 kg (with battery)
- LCD: TFT full color liquid crystal display panel module, 6.5 inch image size, anti-reflective type. Adjustable brightness.
- Still Image Recording Resolution: NTSC: H640 x V480 (Pixel), PAL: H768 x V576 (Pixel)
- Still Image Recording Format: Compressed JPEG (Exif 2 compliant) high (HIGH) or uncompressed TIFF (TIFF-YC) for stereo optical adapters. JPEG (Exif 2 compliant) for other optical adapters (SHQ, high, standard quality selectable).
- Moving Image Recording Resolution: QVGA NTSC: H320 x V240 (Pixel), PAL: H384 x V288 (Pixel); VGA NTSC: H640 x V480 (Pixel), PAL: H640 x V480 (Pixel)
- Moving Image Recording Format: AVI formats (Motion JPEG, Compression rate fixed).
- Audio Recording: WAV format, max. 60 sec.
- Recording Media: CF card (1 GB included), internal memory, USB memory (Olympus recommended).
- Video Signal Outputs: Composite (VBS) video (BNC jack), Y/C (S) video (S video connector).
- Microphone Input: φ3.5 mm monaural mini jack (for plug-in power).
- USB Connector: A connector, Ver.1.1 standards.
- Power Supply: Specified Lithium Ion battery (IDX NP-L7S, 14.8 V) or AC adapter (100-240 V AC, 50/60 Hz, 16 V output).
- Battery Powered Operating Time: 150 minutes or longer (new battery).
Operating Environment
- Operating Temperatures:
- Insertion tube: -25 to 100°C (in air), 10 to 30°C (in water, except IV8635X1)
- Other parts: -21 to 49°C (battery-powered), 0 to 40°C (AC adapter-powered)
- Operating Atmospheric Pressure:
- Insertion tube: 1013 hPa (in air), 1013 to 1772 hPa (under water, except IV8635X1)
- Other parts: 1013 hPa
- Operating Environment Humidity: 15 to 90% (Relative humidity)
- Liquid Resistance (Insertion Tube): No trouble when exposed to machine oil, light oil, or 5% saline solution.
- Waterproofing (Insertion Tube): Waterproof with optical adapter attached (underwater stereoscopic measurement not possible, IV8635X1 not for underwater use).
- Waterproofing (Other Parts): Rain-proof (not rain-proof when battery cover and others are open).
- MIL-STD-810F Compliance: Vibration (Method 514.5), Shock (Method 516.5), Water Resistance (Method 506.4), Humidity (Method 507.4), Salt Fog (Method 509.4), Sand and Dust (Method 510.4), Explosive Atmosphere (Method 511.4), Icing / Freezing Rain (Method 521.2).
- EMC Information: IEC/EN61326-1 Class A (industrial environment).
- FCC and IC Information: Part 15 of FCC Rules, Canadian ICES-003 Class A.
Usage Features
- Portability: The base unit can be placed on its side or base and can be fitted with a shoulder strap for carrying.
- Modular Design: Scope units are replaceable, allowing for different diameters and lengths.
- Optical Adapters: Various optical adapters are available for different fields of view, directions of view, and depths of field, including stereo optical adapters for 3D measurements.
- User Interface: Control unit with joystick for angulation and menu navigation, dedicated buttons for freeze/record, live/gain, view, and menu/exit. LCD monitor with brightness adjustment and image rotation.
- Image Management: Input titles and notes for recorded images, organize images into folders, search by date, and compare two images simultaneously (live and retrieved).
- Measurement Modes: Stereo measurement (Distance, Point to Line, Offset, Depth, Area/Lines, Multi, Profile) and Scaler measurement.
- Spot Ranging: Calculates the approximate distance from the scope tip to the object, indicated by numerical value and a color-coded bar (green for up to 15 mm, yellow for up to 30 mm, red for 30 mm and higher).
- Zoom: Electronic zoom up to 3X for magnified observation images.
- White Balance: Automatic adjustment for accurate color representation.
- Noise Reduction: Two settings (high/standard) to reduce static interference in images.
- Language Selection: Menu display in multiple languages (English, French, Spanish, Japanese, Korean, Chinese, German, Italian, Russian).
- USB Connectivity: Connects to USB memory or USB keyboard (Olympus recommended) for data transfer or text input. Can also connect to a computer via USB.
Maintenance Features
- Cleaning: Regular cleaning of the scope, base unit, battery cover, interface connectors, and optical adapters with a soft cloth and cleaning fluid (provided in the lens cleaning kit). Special care for distal end and O-rings.
- Battery Management: Battery power indicator on the LCD monitor. Recommended to prepare charged spare batteries for long operations or cold weather. Battery is a consumable item and should be replaced when operation time shortens.
- Storage: Store the equipment in a clean, dry, and stable place at normal room temperature and humidity. Secure the carrying case with the belt during transport.
- Hook Assembly Maintenance: Clean the hook assembly with cleaning fluid if contaminated. Store the hook assembly in its designated housing within the carrying case, ensuring it is rolled to a curvature radius of 100 mm or more to prevent deformation.
- Troubleshooting Guide: Comprehensive guide for error messages and general operational issues, including remedies and when to contact Olympus for repair.
- Self-Check Functions: The instrument includes self-check functions that trigger warnings or terminate operations in case of issues like high temperature, insertion tube overload, or battery problems.