Maintenance
Clean the bowl and attachments daily or after use to maintain hygiene standards. Clean the mixer with a soft
wet cloth. The transmission gear box is greased in factory. Check the greasing each 6 months. To add or rell
grease, open the top cover, then ll grease from aperture or replace the grease directly. Ensure guide rails are
kept clean and lubricated.
Troubleshooting
Problems Causes Solutions
Planetary does not rotate after
starting the machine
Loose electric wiring Check electric wiring tighten any
loose connections. Press reset
button.
Oil leakage The seal rings are worn out Replace seal rings
Motor temperature raises while
reduced output speed
Too low voltage Check the power supply
Over-loaded Reduce load
The speed of mixing is too high, or
wrong attachment is being used, or
mixing too long.
Select a suitable speed and
attachment. Reduce load.
The mixing knocks with the bowl The attachment or bowl is
deformed
Repair of replace the attachment
or bowl
Abnormal noise and high
temperature from gearbox
Insufcient lubrication Add or replace the grease
Bowl lift is difcult to pull up Guide rails are not lubricated. Lubricate guide rails.
Warning!
If the equipment is out of function, please make sure it is serviced by a professional person. Please turn to a
special service centre!