L
lunarichardNov 5, 2025
What to do if there is low pressure in the line of my omi ED18?
- TTimothy RodriguezNov 5, 2025
If you're experiencing low pressure in the line of your omi Dehumidifier, consider the following potential causes: * Ice formation in the evaporator: Check the probe; if the trouble persists, replace it. * Electronic control board issue: Contact our Service Centre to check the gas charge. * Clog: Check if the compressed air inlet/outlet is connected properly. * Clogged connecting tubing: Check if the connecting tubing is clogged; in case proceed accordingly. * Closed valves: Check if any valves are closed. * Filter condition: Check the condition of any filter. * Drainage solenoid valve jammed: Clean or replace it. * Condensate drainage times: Verify the condensate drainage times set on the electronic control board (C8 and C9). Check the signal from the control board: if it...