OMNI-624/OMNI-624EU Installation and Setup Guide
6-12
4-digit code of 1234 enter
1
2 3 4
L1 L2 L3 L4 L5 L6
6-digit code of 123456 enter
3
4 5 6 1 2
L1 L2 L3 L4 L5 L6
Note that if the system is set for 4-digit codes and you enter a 6-digit code, the first two digits of the
code (L5 and L6) are stored into memory but will not become active until the system is set for 6-digit
codes (Submode 1, Question 12, L3) and the programming mode ends.
QUESTIONS 0105 TELEPHONE and PAGER NUMBERS
Enter the telephone number (including area code and/or dialing prefix IF NECESSARY) of the primary
central station receiver in Question 01, L1L20.
Example: If the primary telephone number to be entered is: 1-516-123-4567
You would enter (on Programming Worksheet): 15161234567.
Enter the valid digits from the table that follows.
Entry Function Comments
0
90
9
A Signifies end of the phone number Enter after last digit of phone number
B
Star (
)
Enter whenever the star is used
C 3-Second pause Provides delay to wait for dial tone
D Pound (#) Enter whenever the pound is used
E
70C (TouchTone)
1170C (Rotary)
Enter to disable Call Waiting
F 800 Enter to dial 800
REPORTING ROUTE:
The system can report to 1 or 2 central station phone numbers. If you select split reporting, then
OPENING and CLOSING signals will be directed to the secondary phone number, while all other
signals will be transmitted to the primary phone number. If you selected backup reporting, the panel
will alternate between the primary and secondary receivers (if the second phone number is
programmed) for a programmable number of attempts (Question 11, L3) to each phone number in the
event the signal has not been acknowledged. If you selected dual reporting, then signals are sent to
both primary and secondary phone numbers. If neither split nor backup reporting is necessary, then
this question may be left as factory defaulted and all conditions will be routed to the Primary number
only.
Enter the telephone number (including area code or dialing prefix, IF NECESSARY) of the secondary
central station receiver in Question 02, L1L20. An entry of the digit A causes the system to skip that
digit and examine the next digit.