OMNI-624/OMNI-624EU Installation and Setup Guide
6-22
Q 14, L1 – Enter the L1 digit from the table below.
L1
Entry
Stay-
Arms
Stay
No FOB
Auto-
Stay
Instant
Arms
Away
Instant
Enabled
0
1
✔
2
✔
3
✔✔
4
✔
5
✔✔
6
✔✔
7
✔✔ ✔
8
✔
9
✔✔
A
✔✔
B
✔✔ ✔
Stay Arms Stay:
If enabled, the system will arm in the
STAY mode by simply pressing the [STAY] key (user code
not required). Otherwise, the user must press the [STAY]
key followed by the user code to arm in STAY mode. When
you are using the ADEMCO Point ID reporting format and
Stay Arms Stay is enabled, a PID code of 408 with a user
number of 128 is sent to the central station when the
system is armed using the STAY key.
No Fob Auto-Stay:
If selected, the auto-stay feature will
be disabled when arming from an RF keyfob (system will
arm the system in the mode selected).
Instant Arms Away:
If enabled, the system will arm in
the AWAY mode by pressing the [INSTANT] key. When
you are using the ADEMCO Point ID reporting format and
Instant Arms Away is enabled, a PID code of 408 with a
user number of 128 is sent to the central station when the
system is armed using the INSTANT key.
Instant Enabled:
If selected, allows the end user to arm
instant mode. Not available if INSTANT ARMS AWAY is
selected.
Q 14, L2
– Enter the L2 digit from the table below.
L2
Entry
Arm With
Fault
Bypass
Error
Exit
Error
No PC if
Armed
No Arm if
Low Battery
0
✔
1
✔✔
2
✔
3
✔✔
4
✔✔
5
✔✔✔
6
✔✔
7
✔✔ ✔
8
✔✔
9
✔✔ ✔
A
✔✔
B
✔✔ ✔
C
✔✔ ✔
D
✔✔✔✔
E
✔✔✔
F
✔✔ ✔ ✔
Arm With Fault:
Allows the system to
arm even if a delay or interior zone is
faulted. However, faulted zones
must
be
restored
before
exit time expires, or an
alarm will result if the bypass error is
not enabled.
Bypass Error/Exit Error:
If selected,
faulted zones after arming will be
bypassed and no exit error report will be
sent. Otherwise, the normal exit error
report will be sent if there are faulted
zones after arming.
No PC if Armed:
If system is armed,
the control will not communicate with
downloading computer.
No Arm if Low Battery
: If selected,
system will not arm if a system low
battery exists.