Section 6. System Programming
6-21
Q 13, L3 –
Enter the L3 digit from the table below.
Pager Attempts
Supervision
Time (Hours)
L3
Entry123261824
0
disabled
✔
1
✔✔
2
✔✔
3
✔✔
4
disabled
✔
5
✔✔
6
✔✔
7
✔✔
8
disabled
✔
9
✔✔
A
✔✔
B
✔✔
C
disabled
✔
D
✔✔
E
✔✔
F
✔✔
Pager attempts:
This sets the number of times the
system will send a report to a pager.
Supervision Time:
This sets the time interval within
which the RF Receiver must hear from transmitters,
otherwise an RF trouble report will be sent. 24 hours is
recommended for 5800 and ZR-500 RF devices. When
5800EU RF devices are used where compliance to
EN50131-5-3 is required, use a supervision time of 2
hours.
Q 13, L4
– Enter the L4 digit from the table below.
Swinger Count
L4
Entry0123
0
disabled
1
✔
2
✔
3
✔
Swinger Count:
Sets the maximum number of messages (controlled
zone alarms or troubles) sent during an armed period.
QUESTION 14 ARMING OPTIONS
L1 L2 L3 L4
This question defines arming options. Enter the digits as follows: