Page #68 background image
OMNI-624/OMNI-624EU Installation and Setup Guide
6-30
Q 18, L3 AC Dial Delay
AC loss reporting time may be delayed in 15-minute increments for values 1F. Zero selects random
delay, which can be anywhere between 10 and 225 minutes. Enter AC loss dial delay from the table
below.
L3 Entry AC Dial Delay (min) L3 Entry AC Dial Delay (min)
0
random 10225
8
120
1
15
9
135
2
30
A
150
3
45
B
165
4
60
C
180
5
75
D
195
6
90
E
210
7
105
F
225
Q 18, L4 Ring Count
Enter the digit for the desired ring count (number of rings before the system picks up the phone line
when downloading) from the table below.
L4
Entry
Ring
Count
L4
Entry
Ring
Count
0
Disabled *
8
8
1
1
9
9
2
2
A
10
3
3
B
11
4
4
C
12
5
5
D
13
6
6
E
14
7
7
F
15
* If ring count is disabled, the control cannot be
accessed remotely (downloading).
QUESTION 19 EXIT DELAYS/DIALER DELAY
N/U
L1 L2 L3 L4
Part. 1 Part. 2 Abort Dial
Delay time