Connecting via Ethernet Network
For Network connections, check the Connect over Ethernet box and enter the IP address of the Omnia-3fm
Turbo in the box provided. The TCP/IP address entry format is: xxx.xxx.xxx.xxx. The TCP/IP address of the
Omnia-3 Ethernet hardware interface is set during initial configuration.
Technical note: the Omnia 3 Remote Control communicates with the Omnia 3 using a Telnet session on Port
23. If you are unable to communicate with the Omnia through a network firewall, the first thing to check is
whether traffic on port 23 is being permitted.
Enter the password for the unit in the Password box. If nothing is entered, you will be asked for the password at
the time you connect to the remote Omnia. The default passwords for Ethernet remote connections are the same
as the front panel passwords:
Normal: “vito” (all lower case)
Engineer: “tomtom” (all lower case)
The Remote Control software allows multiple connection profiles to be created so that a mix of connection
types (Direct, Serial, TCP/IP) may be used. This allows the program to easily support communicating with
different Omnias at different locations, connected by different means.
When all items have been entered, select OK.
Note: These connection settings are stored in a small binary file named connect.dat located in the same folder
as the remote program.