EasyManuals Logo

Omron 3G3MX2 Series Connection Guide

Omron 3G3MX2 Series
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
3. Remarks
3
3. Remarks
(1) Understand the specifications of devices which are used in the system. Allow some
margin for ratings and performance. Provide safety measures, such as installing safety
circuit in order to ensure safety and minimize risks of abnormal occurrence.
(2) To ensure system safety, always read and heed the information provided in all Safety
Precautions, Precautions for Safe Use, and Precaution for Correct Use of manuals for
each device which is used in the system.
(3) The users are encouraged to confirm the standards and regulations that the system must
conform to.
(4) It is prohibited to copy, to reproduce, and to distribute a part of or whole part of this
document without the permission of OMRON Corporation.
(5) This document provides the latest information as of March 2013. The information
contained in this document is subject to change for improvement without notice.
About Intellectual Property Right and Trademarks
Microsoft product screen shots reprinted with permission from Microsoft Corporation.
Windows is a registered trademark of Microsoft Corporation in the USA and other countries.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation
GmbH, Germany.
Company names and product names in this document are the trademarks or registered
trademarks of their respective companies.

Other manuals for Omron 3G3MX2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3MX2 Series and is the answer not in the manual?

Omron 3G3MX2 Series Specifications

General IconGeneral
Frequency Range0.1 to 400 Hz
Control MethodV/f Control, Sensorless Vector Control
Overload Capacity150% for 60 seconds
Safety StandardCE, UL, cUL
IP RatingIP20
Output Voltage3-phase 200-240V AC
Output Frequency0.1 to 400 Hz
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground fault, Short circuit
Ambient Temperature-10 to 50°C
Operating Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5% to 95% RH (non-condensing)
AltitudeUp to 1000 m
Braking UnitBuilt-in
CommunicationModbus RTU
Communication InterfaceRS-485
Cooling MethodForced air cooling
Enclosure RatingIP20
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload