EasyManuals Logo

Omron CK3E Series Startup Guide

Omron CK3E Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
61
9
[Slot1(NX-SL3500)Output Data
Set1]
Registering Node1/Unit3
(NX-SOD400)
Click New in the Variables tab
page, and register 4 variables
shown on the right.
FSoE Master CMD
#x7040:01
USINT
Safety Output 1st Byte
#x7041:01
USINT
Group: Module 1(NX-SL3500).Output Data Set 1
Datatype : USINT
Count : 2
FSoE Master CRC_0
#x7040:03
UINT
FSoE Master Conn_ID
#x7040:02
UINT
Group: Module 1(NX-SL3500).Output Data Set 1
Datatype : UINT
Count : 2