Enclosed Switch D4C F-19
Limit
Switches
Engineering Data
Electrical Durability
Leakage Current for LED-indicator Models
Model Voltage Leakage current Resistance
D4C-2@@@ 125 VAC 1.7 mA 68 k
D4C-3@@@ 30 VDC 1.7 mA 15 k
D4C-5@@@ 125 VAC 1.7 mA 68 k
D4C-6@@@ 30 VDC 1.7 mA 15 k
0
10
50
100
300
500
1,000
3,000
5,000
30
50
100
300
500
1,000
3,000
10,000
5,000
7,000
30
0 20 40 60 80 100 120
1234567
Operating frequency: 30 operations/min
(cos
φ
= 1, L/R = 0)
Operating temperature: 5
°
C to 35
°
C
Operating humidity: 40% to 70%
Operating frequency: 30 operations/min
(cos
φ
=1, L/R = 0)
Switching current (mA) Switching current (mA)
Durability (x 10
3
operations)
Durability (x 10
3
operations)
D4C-4@@@, -5@@@, -6@@@
30 VDC
125 VAC
125 VAC
250 VAC
D4C-1@@@, -2@@@, -3@@@