F-14 Enclosed Switch D4C
Remarks
There is no difference in mounting pitch between the Mounting Plate
and the WL. The mounting depth of the D4C with the Mounting Plate
attached is, however, shorter than that of the panel-mounted WL.
Specifications
■ Approved Standards
Note 1: Models with VCTF oil-resistant cables only.
2: Pre-wired models only.
3: SJT(0)-cable models only.
■ Approved Standard Ratings
General Ratings
Plate
WL D4C
Agency Standard File No.
TÜV Rheinland EN60947-5-1 R9451333 (see note 1)
J9950970 (see note 2)
UL UL508 E76675 (see note 3)
CSA CSA C22.2 No. 14 LR45746 (see note 3)
Model Rated voltage Non-inductive load Inductive load Inrush current
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO NC NO
D4C-1@@@ 125 VAC 5 A 5 A 1.5 A 0.7 A 3 A 3 A 2.5 A 1.3 A 20 A
max.
10 A
max.
250 VAC 5 A 5 A 1 A 0.5 A 2 A 2 A 1.5 A 0.8 A
8 VDC 5 A 5 A 2 A 2 A 5 A 4 A 3 A 3 A
14 VDC 5 A 5 A 2 A 2 A 4 A 4 A 3 A 3 A
30 VDC 4 A 4 A 2 A 2 A 3 A 3 A 3 A 3 A
125 VDC 0.4 A 0.4 A 0.05 A 0.05 A 0.4 A 0.4 A 0.05 A 0.05 A
250 VDC 0.2 A 0.2 A 0.03 A 0.03 A 0.2 A 0.2 A 0.03 A 0.03 A
D4C-2@@@ 125 VAC 5 A 5 A 1.5 A 0.7 A 3 A 3 A 2.5 A 1.3 A
125 VDC 0.4 A 0.4 A 0.05 A 0.05 A 0.4 A 0.4 A 0.05 A 0.05 A
D4C-3@@@ 30 VDC 4 A 4 A 2 A 2 A 3 A 3 A 3 A 3 A
D4C-4@@@ 125 VAC 0.1 A 0.1 A --- ---
8 VDC 0.1 A 0.1 A
14 VDC 0.1 A 0.1 A
30 VDC 0.1 A 0.1 A
D4C-5@@@ 125 VAC 0.1 A 0.1 A --- ---
D4C-6@@@ 30 VDC 0.1 A 0.1 A --- ---