A Appendices
A - 38
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
This object sets the alarm output level of the Sensor with the unit number that is specified by the index.
This object executes the maximum sensitivity tuning for the Sensor with the unit number that is
specified by the index.
Set this object to 0001 hex to write data. It is always set to 0000 hex when reading data.
Allow at least 3 seconds for processing to be completed after executing full auto tuning setup.
This object executes the zero reset for the Sensor with the unit number that is specified by the index.
Set this object to 0001 hex to execute and 0000 hex to reset.
On the CA0, zero reset cannot be executed when the detection method is set to color mode.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
This object turns OFF the emitted light for the Sensor with the unit number that is specified by the
index.
It is always set to 0000 hex when reading data.
4025 + (N-1) × 80
hex
No_01 ... 30 Alarm Output Level Setting
Subindex 0: Number of Entries
Range: 01 hex Unit: --- Default: 01 hex Attribute: ---
Size: 1 byte (U8) Access: RO PDO map: Not possible
Subindex 1: No_01 ... 30 Alarm Output Level Setting
Range: 0000 to 0064 hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
4030 + (N-1) × 80
hex
No_01 ... 30 Maximum Sensitivity Tuning
Subindex 0: Number of Entries
Range: 02 hex Unit: --- Default: 02 hex Attribute: ---
Size: 1 byte (U8) Access: RO PDO map: Not possible
Subindex 1: No_01 ... 30 Maximum Sensitivity Tuning IN1
Range: 0000 to 0001 hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
Subindex 1: No_01 ... 30 Maximum Sensitivity Tuning IN2
Range: 0000 to 0001 hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
4031 + (N-1) × 80
hex
No_01 ... 30 Zero Reset
Subindex 0: Number of Entries
Range: 02 hex Unit: --- Default: 02 hex Attribute: ---
Size: 1 byte (U8) Access: RO PDO map: Not possible
Subindex 1: No_01 ... 30 Zero Reset IN1
Range: 0000 to 0001 hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
Subindex 2*: No_01 ... 30 Zero Reset IN2
Range: 0000 to 0001 hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
4032 + (N-1) × 80
hex
No_01 ... 30 Projection Lighting OFF
Subindex 0: Number of Entries
Range: 02 hex Unit: --- Default: 02 hex Attribute: ---
Size: 1 byte (U8) Access: RO PDO map: Not possible
Subindex 1: No_01 ... 30 Projection Lighting OFF IN1
Range: 0000 to 0001 hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible
Subindex 2*: No_01 ... 30 Projection Lighting OFF IN2
Range: 0000 to 0001 hex Unit: --- Default: --- hex Attribute: A
Size: 2 bytes (U16) Access: RW PDO map: Not possible