EasyManua.ls Logo

Omron E3Z-LS - Operation; NPN Output

Omron E3Z-LS
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
E3Z-LSE3Z-LS
Operation
Note: The VERY FAR region is supported only for FGS. The in-
cident light level threshold is fixed and cannot be set.
NPN Output
NEAR FAR VERY FAR
Distance threshold
(set distance)
Incident light level
threshold (not settable)
Only for FGS
mode
Model Output
transis-
tor sta-
tus
Timing chart Mode
selec-
tion
switch
BGS/FGS
selection
method
Output circuit
E3Z-LS61
E3Z-LS66
Light ON L side
(L/ON)
BGS:
Either
leave the
pink wire
(2) open or
connect it
to the blue
wire (3).
Dark ON D side
(D/ON)
Light ON L side
(L/ON)
FGS:
Connect
the pink
wire (2) to
the brown
wire (1).
Dark ON D side
(D/ON)
ON
OFF
ON
OFF
ON
OFF
NEAR FAR
Operation
indicator
(orange)
Output
transistor
Load (e.g.,
relay)
(Between brown and black)
1
2
4
3
4
2
1
3
0 V
Z
D
Operation
indicator
(orange)
Stability
indicator
(green)
Main
circuit
(Control
output)
Brown
Black
Pink
Blue
FGS
100 mA
max.
12 to 24 VDC
Load (relay)
BGS
Connector Pin Arrangement
ON
OFF
ON
OFF
ON
OFF
NEAR FAR
Operation
indicator
(orange)
Output
transistor
Load (e.g.,
relay)
(Between brown and black)
ON
OFF
ON
OFF
ON
OFF
NEAR FAR
VERY FAR
Operation
indicator
(orange)
Output
transistor
Load (e.g.,
relay)
(Between brown and black)
ON
OFF
ON
OFF
ON
OFF
NEAR FAR
VERY FAR
Operation
indicator
(orange)
Output
transistor
Load (e.g.,
relay)
(Between brown and black)

Related product manuals