H3DS-jLC
H3DS-jLC
33
Installation of Screwless Spring Terminal Models
Tools
A
flat-blade screwdriver should be used to mount the cables.
Applicable
Screwdriver
F
Flat-blade, Parallel-tip, 2.5 mm diameter
F
Flat-blade, Parallel-tip
F
Flat-blade, Flared-tip
2.5 dia.
Cannot be used.
Examples: FACOM AEF
.2.5
×
75E
VESSEL No. 9900-(-)2.5
×
75
WAGO 210-119
WIHA 260/2.5
×
40
Applicable Wires
Applicable Wire Sizes
0.2
to 1.5 mm
2
, A
WG24 to A
WG16
Applicable Wire Type
Solid
wires, stranded wires, flexible wires, or wires with ferules can
be
used.
(See note 1) < 1.8
x
Diameter D (mm)
x
3.0 (see note 2)
Conductor
diameter d (mm) or length of sides a and b (mm)
x
1.6
Wires
with Ferules
Note: 1. If
the overall diameter of the wire is less than 1.8 mm, do
not insert the wire past the conductor. Refer to the fol-
lowing
diagrams.
OK NG
2. If
the overall diameter of the wire is over
2.8 mm, it will be
difficult
to use double wiring.