H5CC
1212
Dimensions (Unit: mm)
Digital Timers
Digital Timers
Dimensions with Flush Mounting Adapter
Dimensions with Front Connecting Socket
H5CC-A/-AD/-AS/-ASD/-AU/-AUD/-AWSD (Flush Mounting Models)
Note: M3.5 terminal screw
(effective length: 6 mm)
H5CC-A11/-A11D/-A11F/-A11S/-A11SD (Flush Mounting/Surface Mounting Models)
44.8 x 44.8
63.7
14.4
6
48 x 48
H5CC-L8/-L8D/-L8S/-L8SD/-L8E/-L8ED/-L8EF (Flush Mounting/Surface Mounting Models)
63.7
14.4
6
48 x 48
44.8 x 44.8
58
48
48
7.5
57.5
H5CC-A/-AD/-AS/-ASD/-AU/-AUD/-AWSD (Flush Mounting Models)
(Provided with Adapter and Waterproof Packing)
Panel Cutouts
Panel cutouts are as shown below. (According to DIN 43700.)
Note: 1.
The mounting panel thickness should be 1 to 5 mm.
Note: 2. To allow easier operation, it is recommended that
Adapters be mounted so that the gap between
sides with hooks is at least 15 mm (i.e., with the
panel cutouts separated by at least 60 mm).
Note: 3. It is possible to horizontally mount Timers side by
side. Attach the Flush Mounting Adapters so that
the surfaces without hooks are on the sides of the
Timers. If they are mounted side-by-side, water
resistance will be lost.
60 min.
60 min.
15 min.
45
+
0.6
0
45
+
0.6
0
A
With Y92A-48F1 attached.
With Y92A-48 attached.
A=(48n2.5)
+1
0
A=(51n5.5)
+1
0
A={48n2.5+(n1)u4}
+1
0
n Units mounted
side by side
H5CC-L8/-L8D/-L8S/-L8SD/-L8E/-L8ED/-L8DF/
-A11/-A11D/-A11F/-A11S/-A11SD (Flush Mounting Models)
(Adapter and Waterproof Packing Ordered Separately)
P2CF-08(-E)/P2CF-11(-E) (order separately)
Front Connecting Socket
100.9
103.2
H5CC-A11@/-L8@
*
* These dimensions depend on the kind of DIN track and Sockets.
(Reference value.)