Operating Procedures of the H5CC-AWSD
Operation in Run Mode
Forecast Value Setting Absolute Value Setting
Operation in Function Setting Mode
Set the digits for the set values using the corresponding UP1 to UP6 Keys (DW1 to DW6 Keys).
*
0.0
0.0
0.0
0.0
Set value
Present value
Forecast set value
Present value
* Each time the UP1 + UP3 or
DW1 + DW3 are pressed,
the sub-display will switch
between the set value
(“SET” is lit) and the forecast
set value (“1” is lit).
*
0.0
0.0
0.0
0.0
Set value 1
Present value
Set value 2
Present value
* Each time the UP1 + UP3 or
DW1 + DW3 are pressed,
the sub-display will switch
between set value 1 (“SET
1” is lit) and set value 2
(“SET 2” is lit).
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the
mode is changed to run mode. Also, when settings are changed, the timer is reset (time
initialized and output turned OFF).
Time Range List
• Set the time range using the UP1 Key (DW1 Key).
For details, refer to the Time Range List.
• Set the output mode using the UP1 Key (DW1 Key).
• Set the input signal width using the UP1 Key (DW1 Key).
• Set the NPN/PNP mode using the UP1 Key (DW1 Key).
Function
setting mode
*2
*1
* Use UP1+UP3 to move up and
DW1+DW3 to move down
Display Set Value
0.01 s to 9999.99 s
(default setting)
0.1 s to 99999.9 s
1 s to 999999 s
0 h 0 min 01 s to 99 h 59 min 59 s
0 h 01 min to 9999 h 59 min
0.1 h to 99999.9 h
1 h to 999999 h
0.001 s to 999.999 s
0.1 min to 99999.9 min
1 min to 999999 min
9999991
999999
sl1h
shs
……
s
-----.-
------
---.---
----.--
*
*
*
20ms 1ms
(F-1)(A)
a f-1
a
outm
20m5
iflt
*
pnpnpn
npn
imod
Change to Function Setting Mode.
To
next page
From
next page
The characters displayed in reverse video are the default settings. In the function setting mode, the status indicators of the
keys that can be set light up.
(Example) In the case of the set value upper limit
A value from 1 to 999999 can be set, and therefore the status indicators of the UP1 to UP6 Keys (DW1 to DW6 Keys) light up.
• Set the digits for the set values using the corresponding
UP1 to UP6 Keys (DW1 to DW6 Keys).
Set value
upper limit
Time range
Output
modes
(1 ms)(20 ms)
Input signal
NPN/PNP
input
(PNP input)(NPN input)
Function Setting Mode
----.--
timr
----.--
s
-----.-
s
------
s
--:--:--
hm s
s
----:--
hm
-----.-
h
------
h
---.---
-----.-
m
------
m
(999999)(1)
Run mode
Power ON
UP1+UP3 or DW1+DW3
(Press and hold for 2 s)
UP1+UP3 or DW1+DW3
(Press and hold for 2 s)