Examples
Run Mode
Changing the Set Value
Tochange theset value from 3 hr 5min to 4 hr 5 min, press the 3 key
so that the number 4 appears in the hour’s place.
#
Pressing keys 1 through 4 increments the corresponding
column by 1.
#
The columns can be changed in any order, but the output will
be turned ON if the set value is less than the present value.
#
Nonsignificant zeros are normally not shown on the set value
display.
Note: Read
Changing Set Values
in the
Precautions
section, pg.
15, before changing the Timer set value during operation.
Changing the Batch Count Set Value
1. Press theBATCH key to switch from the present value display to
the batch count display.
2. Change the set value when the Timer is set to the batch count
display.
#
Nonsignificant zeros are normally suppressed on the batch
count set value display.
#
Press the DISPLAY key to switch back from the batch count
display to the present value display.