EasyManuals Logo

Omron H7CX Series User Manual

Omron H7CX Series
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
16
H7CX (Counter Function)H7CX (Counter Function)
Key Protect Level (
*7/3
)
Set the key protect level.
When the key-protect switch in set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specify-
ing the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status
of the key-protect switch after the H7CX is mounted to the panel.
Note: Changing mode to configuration selection mode ( + 1 s min.) or function setting mode ( 3 s min.).
Level Meaning Details
Changing mode
(See note.)
Switching display
during operation
Reset key Up/down key (Up key
for 6-digit models)
KP-1 (default setting) No Yes Yes Yes
KP-2 No Yes No Yes
KP-3 No Yes Yes No
KP-4 No Yes No No
KP-5 No No No No
ON
OFF
Note: Factory-set to OFF
Key protect indicator
(See note)
MODE
1
MODE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H7CX Series and is the answer not in the manual?

Omron H7CX Series Specifications

General IconGeneral
Input SignalContact
Power Supply12-24 VDC or 100-240 VAC
OutputRelay
MountingPanel mount
Storage Temperature-25 to 65°C (with no icing or condensation)
Weight200 g