35
H7CXH7CX
678910
11 12 13
OUT1
(+)
()
12345
OUT2
()
(+)
0 V
678910
11 12 13
(+)()
12345
OUT1
OUT2
()
(+)
0 V
678910
11 12 13
0 V
12345
(+)(
)
OUT1
OUT2
678910
11 12 13
(+)(
)
12345
OUT1 or 2
OUT 1 or 2
()
(+)
0 V
678910
11 12 13
(+)()
12345
OUT1 or 2
OUT 1 or 2
()
(+)
0 V
H7CX-AW/-A4W/-AWD1
2-stage Contact Output
H7CX-AWS/-A4W/-AWSD1
2-stage Transistor Output
H7CX-AWSD/-A4WSD
2-stage Transistor Output
H7CX-AUSD1
2-stage Transistor Output
H7CX-AU/-AUD1
1-stage Contact, 1-stage Transistor Output
Reset 1
CP2
CP1
Reset 2
Sensor, etc.
12 VDC
External power
supply
Reset 1
CP2
CP1
Reset 2
Sensor, etc.
12 VDC
External power
supply
Reset 1
CP2
CP1
Reset 2
Sensor, etc.
12 VDC
External power
supply
Reset 1
CP2
CP1
Reset 2
Unused
Reset 1
CP2
CP1
Reset 2
Sensor, etc.
12 VDC
External power
supply
Note: 1. Terminals 1 and 6 are connected internally.
2. Do not connect unused terminals as relay terminals
Note: Each output can be flexibly allocated to either stage 1
or 2 by setting in function selection mode.
Note: Each output can be flexibly allocated to either stage 1
or 2 in function selection mode.