23
11. Guidance and Manufacturer’s Declaration
Electrical fast
transient/burst
IEC 61000-4-4
±2 kV for
power supply
lines
±1 kV for
input/output
lines
Not
Applicable.
Not Applicable.
Surge
IEC 61000-4-5
±1 kV line(s)
to line(s)
±2 kV line(s)
to earth
Not
Applicable.
Not Applicable.
Voltage
dips, short
interruptions
and voltage
variations on
power supply
inputlines
IEC 61000-4-11
<5 % U
T
(>95 % dip
in U
T
) for 0.5
cycle
Not
Applicable.
Not Applicable.
40 % U
T
(60 % dip
in U
T
) for 5
cycles
70 % U
T
(30 % dip in
U
T
) for 25
cycles
<5 % U
T
(>95 % dip in
U
T
) for 5 sec.
Power
frequency
(50/60 Hz)
magnetic eld
IEC 61000-4-8
3 A/m 3 A/m
Power frequency magnetic elds
should be at levels characteristic
of a typical location in a
typical commercial or hospital
environment.
Note: U
T
is the A.C. mains voltage prior to application of the test level.