2-2
List of Settings Section 2
List of
Settings
Status (K3HB)
Note The output status turns ON and OFF whether or not an Output Unit is mounted. The output status is
undefined if there is no output terminal when Unit 3 outputs a two-relay comparative output pattern. If
the output is a two-relay plus one-relay comparative output pattern, LL turns ON when PASS turns ON
(output and display colors are not changed in communications status). A 5-output judgement is per-
formed internally regardless of the number of output points. The LL output is always ON in the above
configuration so the PASS output does not turn ON. To avoid this situation, the HH/LL status is ignored
when Unit 3 uses a two-relay output pattern. The PASS judgement is performed with just H and L for
operations like that described.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0 (OFF)
1 (ON)
OFF ON
OFF
ON
OFF ON
OFF ON
Output MAX value MIN value
Present value
Status
No measurement status
Measurement outside the
display range
Input error A
Input error B
No measurement status
Measurement outside the
display range
Input error A
Input error B
No measurement status
Measurement outside the
display range
Input error A
Input error B
Comparative set value LL (1)
Comparative set value L (2)
Comparative set value PASS (3)
Comparative set value H (4)
No Error
No Error
No Error
No Error
No Error
No Error
No Error
No Error
No Error
No Error
No Error
No Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Bit position
16171819202122232425262728293031
0 0
15
TIMING
0 (OFF)
0 (OFF)
1 (ON)
1 (ON)
OFF ON
OFF ON
ON
OFF
OFF
OFF
OFF
---
ON
ON
OFF
OFF
ON
---
OFF ON
OFF ON
OFF ON
OFF ON
OFF ON
OFF ON
ZERO/COMPENSATION
BANK 1
BANK 4
BANK 2
RESET
HOLD
S-TMR
Operation status Control inputs Control inputs Outputs
Bit position
Status
Comparative set value HH (5)
Error output
Not used
Not used
Setting area
Write via communications
Forced zero
Tare zero
Setting Area 0
Setting Area 1
OFF (Disabled)
ON (Enabled)

Table of Contents

Other manuals for Omron K3HB-R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron K3HB-R and is the answer not in the manual?

Omron K3HB-R Specifications

General IconGeneral
BrandOmron
ModelK3HB-R
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals