EasyManua.ls Logo

Omron K3HB - Wiring and Connections; Terminal Arrangement and Power Supply; Sensor Power Supply and Output Wiring; Output Wiring: Relays, Transistors, BCD, DeviceNet

Omron K3HB
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 Digital Indicators K3HB-X/-V/-H/-S
Connections
Terminal Arrangement
Note: Insulation is used between signal input, event input, output, and power supply terminals.
B1
B2
B3
B4
B5
B6
B1
B2
B3
B4
B5
B6
B1
B2
B3
B4
B5
B6
+
+
SD
RD
SG
N/C
B (+)
A (
)
B (+)
A (
)
B (+)
A (
)
B (+)
A (
)
SD
RD
SG
N/C
0-20/
4-20 mA
N/CN/C
0-5/1-5/
0-10 V
N/CN/C
0-5/1-5/
0-10 V
+
+
+
N/C
+
PA SS
N/C
B1
B2
B3
B4
B5
B6
ABCDE
1
2
3
4
5
6
A
Operating Power Supply
B
Sensor Power Supply/Output
C
Relays, Transistors, BCD and DeviceNet
A1
A2
5V
HH
H
L
LL
PASS
HH
H
L
LL
PASS
Contact output Transistor Output
(NPN Open Collector)
Always use a EN/IEC-compliant power supply with reinforced insulation or
double insulation for the DeviceNet power supply.
The product must be used indoors for the above applicable standards to
apply.
Safety Standards Conformance
100 to 240 VAC
24 VAC/ VDC
*Check the required power supply type.
12 VDC 80 mA
12 VDC 80 mA
10 VDC 100 mA
10 VDC 100 mA
12 VDC 80 mA
10 VDC 100 mA
12 VDC 80 mA
10 VDC 100 mA
Sensor power supply +
PASS output
Sensor power supply +
linear output
12 VDC 80 mA
12 VDC 80 mA
10 VDC 100 mA
10 VDC 100 mA
Sensor power supply +
communications
Sensor power
supply
Sensor power supply
<K33-
CPB>
<K33-
CPA>
<K33-B>
<K33-A>
<K33-
L2B>
<K33-
L1B>
<K33-
L2A>
<K33-
L1A>
RS-485
<K33-
FLK3B>
RS-232C
<K33-
FLK1B>
RS-485
<K33-
FLK3A>
RS-232C
<K33-
FLK1A>
Sensor power
supply
Sensor power
supply
Sensor power
supply
0-20/
4-20 mA
The K3HB-XVA@@ complies with UL standards when the applied input
voltage is within the range 0 to 150 VAC.
The BCD COMMON is shared.
The pins indicated in the above diagram
as blank (white) boxes have been removed.
*
Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet.
DeviceNet Connector (Included)
<DRT>
1 2 3 4 5
Relay Outputs
<C2>
Relay Outputs
<C1>
Transistor Outputs
<T1> <T2>
NPN
PNP
HH
H
PASS
L
LL
COM
C1
C2
C3
C4
C5
C6
HH
H
COM
L
H
L
LL
COM
C1
C2
C3
C4
C5
C6
C1
C2
C3
C4
C5
C6
BCD (NPN Open Collector): BCD
Applicable Connector (Sold separately)
HDR-E50MAG1
(HONDA TSUSHIN KOGYO CO., LTD.)
Special Cable (Sold separately)
K32-BCD (OMRON)
(HDR-E50MAG1 with 0.3-m cable)
1: V (Power supply cable: Black)
2: CAN L (Communications cable: Blue)
3: Shield
4: CAN H (Communications cable: White)
5: V+ (Power supply cable: Red)
Applicable Connector:
HR31-5.08P-5SC (01)
(HIROSE ELECTRIC CO., LTD.)
* Attach the provided crimp terminals.

Other manuals for Omron K3HB

Related product manuals