NOTES ON SAFETY
Warning
Conducting self-diagnosis and/or treatment based on the
measurement results can be dangerous. Be sure to follow the
instruction of your doctor.
Self-diagnosis may worsen the symptoms.
Be sure to attach the probe cover exclusive for this unit before
taking measurement.
The infrared sensor may become dirty and correct measurement
result may not be possible.
Do not use the probe cover that was used by someone else.
You may be exposed to infectious diseases such as otitis externa.
If the probe cover becomes dirty with earwax or other substances,
replace it with a new one.
Correct measurement result may not be possible.
Do not touch the infrared sensor with the finger or breathe on it.
The infrared sensor may become dirty and correct measurement
result may not be possible.
If the infrared sensor becomes dirty, lightly wipe it with a soft dry
cloth.
If you wipe it with a tissue paper or a paper towel, the infrared
sensor will be damaged and may not be able to measure correctly.
Store the unit out of children's reach.
Children may try to measure by themselves and cause damage
to the ear. If a child accidentally swallows a battery or a probe
cover, immediately consult with the doctor.
If the ear is cooled such as being exposed to the cold for a long
period, wait until the ear is warmed up, then measure.
The measured result may be indicated low when you use an ice
bag or immediately after coming home from outside in winter.
If there is a difference in temperature between the place where the
unit is stored and the place where you are going to measure, leave
the unit in the room where you are going to use for more than
thirty minutes, then measure.
Correct measurement result may not be possible.
Asia EN-02-20[MC-510]-9 10/1/03 11:59 AM Page 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MC-510 Gentle Temp and is the answer not in the manual?

Omron MC-510 Gentle Temp Specifications

Power IconPower
voltage3 VDC
power consumption0.05 W
battery lifeMeasurements of approx. 2000 times
Temperature Measurement IconTemperature Measurement
temperature indicationIn 3 digits in +°C or 4 digits in +°F
precision±0.3°C (±0.5°F) or ±0.2°C (±0.4°F)
measurement range34 to 42.2°C (93.2 to 108°F)
Operating Environment IconOperating Environment
operating temperature10 to 40°C (50 to 104°F)
operating relative humidity30 to 85%
storage temperature-20 to 60°C (-4 to 140°F)
storage relative humidity10 to 95%
Weight and Dimensions IconWeight and Dimensions
weightApprox. 50g
external dimensionsApprox. 45 (W) x 94 (H) x 58 (D)