3 Error Tables
3-34
NJ-series Troubleshooting Manual (W503)
5401546C hex Master Sync Start
Position Setting
Out of Range
The parameter specified for
the MasterSyncPosition
input variable to a motion
control instruction is out of
range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
5401546D hex Slave Sync Start
Position Setting
Out of Range
The parameter specified for
the SlaveSyncPosition
input variable to a motion
control instruction is out of
range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
5401546E hex Duplicate Latch ID
for Trigger Input
Condition
The same latch ID was
specified for more than one
motion control instruction.
The same latch ID is
used simultaneously
for more than one of
the following instruc-
tions:
MC_TouchProbe
(Enable External
Latch) instruction,
MC_MoveLink (Syn-
chronous Positioning)
instruction, and
MC_MoveFeed (Inter-
rupt Feeding) instruc-
tion.
The MC_AbortTrigger
(Disable External
Latch) instruction was
executed to cancel a
latch that was used by
an instruction other
than the
MC_TouchProbe
(Enable External
Latch) instruction.
S Same as
above.
5401546F hex Jerk Override Fac-
tor Out of Range
The parameter specified for
the JerkFactor input vari-
able to a motion control
instruction is out of range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
54015470 hex Accelera-
tion/Deceleration
Override Factor
Out of Range
The parameter specified for
the AccFactor input vari-
able to a motion control
instruction is out of range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
54015471 hex First Position
Method Specifica-
tion Out of Range
The parameter specified for
the StartMode input vari-
able to a motion control
instruction is out of range.
Instruction input
parameter exceeded
the v
alid range of the
input variable.
S Same as
above.
54015472 hex Motion Control
Instruction Re-exe-
cution Disabled
(First Position
Method)
An attempt was made to
change the StartMode
input variable when re-exe-
cuting a motion control
instruction. (This input vari-
able cannot be changed
when re-executing an
instruction.)
A parameter for an
input variable that can-
not be changed for re-
execution was
changed.
S Same as
above.
54015474 hex Unused Axis Spec-
ification for Auxil-
iary Axis
The axis specified for the
Auxiliary input variable to a
motion control instruction is
an unused axis.
The axis specified for
the Auxiliary input
variable to the instruc-
tion is an unused axis.
S Same as
above.
Event code Event name Meaning Assumed cause