EasyManuals Logo

Omron ns series Setup Manual

Omron ns series
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #218 background imageLoading...
Page #218 background image
7-3 Troubleshooting and Maintenance
Symptoms at
PT
Causes Measures
Cannot input
numerical val-
ues.
The numerical
value input upper
and lower limit
check function is
running.
Display the Expansion Tab from the functional object prop-
erty setting using the CX-Designer. Check the set values in
the Input Upper and Lower Limits Tab Page and correct if
necessary.
The control flags
set in the objects
include Input Pro-
hibit Flags.
Display the Expansion Tab from the functional object prop-
erty settings using the CX-Designer. Select Enable for Input
in the Control Flag Tab Page.
Turn ON the indirect address of the control flag set for the
object.
Cannot input
for some func-
tional objects.
A password has
been set.
Input the password in the password input dialog box that is
displayed.
Cannot input
to any func-
tional object.
PT is set to input
prohibit mode.
Set system memory bit $SB19 to OFF.
Touch the screen and input the password to cancel dis-
abling inputs.
Cannot move
to System
Menu.
Moving to System
Menu is prohibited.
Set system memory bit $SB3 to OFF.
There is no refer-
ence file.
Use the CX-Designer to check whether the folder storing
project data contains a reference file, and resend the
screen data to the PT.
The list selec-
tion and bit-
map object are
blank.
The number of
rows specified in
the first row of the
list selection is
above the maxi-
mum.
Set the number of rows to less than the maximum.
7-13

Table of Contents

Other manuals for Omron ns series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ns series and is the answer not in the manual?

Omron ns series Specifications

General IconGeneral
BacklightLED
Power Supply24 VDC
Display TypeTFT LCD
Display Size5.7 to 12.1 inches (depending on the model)
Resolution320 x 240 to 800 x 600
InterfaceEthernet, USB
MemoryVaries by model
Operating Temperature0 to 50°C
Protection LevelIP65 (front panel)
Storage Temperature-20 to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s²
Power ConsumptionVaries by model

Related product manuals