5 I/O Refreshing
5 - 28
NX-series Digital I/O Unit User’s Manual (W521)
This uses the I/O ports of the output set values.
Two-point Output Units
I/O Port
I/O port name Type R/W Name Description
Default
value
Unit
Output Bit 00 BOOL RW Output Bit 00 The output set value for output
bit 00.
FALSE
Output Bit 01 BOOL RW Output Bit 01 The output set value for output
bit 01.
FALSE
Output Bit 00
Time Stamp
ULINT RW Output Bit 00 Time
Stamp
The specified operation time for
output bit 00. If the value is 0,
the output is refreshed immedi-
ately.
0ns
Output Bit 01
Time Stamp
ULINT RW Output Bit 01 Time
Stamp
The specified operation time for
output bit 01. If the value is 0,
the output is refreshed immedi-
ately.
0ns
Output Bit 00
Output Status
BOOL RO Output Bit 00 Out-
put Status
The specified time output sta-
tus for output bit 00.
FALSE
Output Bit 01
Output Status
BOOL RO Output Bit 01 Out-
put Status
The specified time output sta-
tus for output bit 01.
FALSE