7 Troubleshooting
7-20
NJ/NX-series Database Connection CPU Units User’s Manual (W527)
Event name
DB Connection Disconnected Error
Event code
85100000hex
Meaning
The DB Connection was disconnected due to an error.
Source PLC Function Module Source details DB Connection
Service
Detection
timing
When a DB
Connection
Instruction is
executed, or
when Spool data
is resent
Error attributes Level Minor fault Recovery Automatic
recovery
Log category System
Effects
User program
Continues.
Operation
Not affected.
System-defined
variables
Variable
Data type
Name
_DBC_Status
_sDBC_STATUS
DB Connection Service Status
Cause and
correction
Assumed cause
Correction
Prevention
The power supply to the server is
OFF.
Check the server status and start it
properly.
Check the server status and start it
properly.
The DB is stopped in the server.
The Ethernet cable connector is
disconnected.
Reconnect the connector and
make sure it is mated correctly.
Connect the connector securely.
The Ethernet cable is broken. Replace the Ethernet cable. None
Noise Implement noise countermeasures
if there is excessive noise.
Implement noise countermeasures
if there is excessive noise.
Attached
information
Attached information 1: DB Connection Name
Precautions/
Remarks
None