4 Basic Operations and Status Check
4-10
NJ/NX-series Database Connection CPU Units User’s Manual (W527)
Checking the Status with a System-defined Variable
You can check the operation status of the DB Connection Service with the _DBC_Status
system-defined variable.
Use this variable when checking the status of the DB Connection Service from the user program
or checking the shutdown of the DB Connection Service from an HMI.
_DBC_Status system-defined
variable
Status
Member
Meaning
Initializing
Running
(Operation
Mode)
Running
(Test
Mode)
Idle
Error
Shut
down
Run
Running flag
FALSE
TRUE
TRUE
FALSE
FALSE
FALSE
Test
Test mode
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
Idle
Idle
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
Error
Error stop flag
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
Shutdown
Shutdown
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE