BU1002SWG / BU3002SWG
<BU3002SWG>
The UPS has been charged prior to shipment. However, the backup time becomes shorter when
using it for the rst time due to spontaneous discharge.
We recommend charging the UPS before using it.
When the AC input plug is connected to a wall outlet (commercial power), the battery automati-
cally starts charging, taking up to 8 hours to complete (24 hours when an additional battery unit
is connected).
You can perform "2-4 Checking the operation" on page 22 also before charging the battery.
Input plug (CEE 7/7)
(Front view)
When one wire is used to ground the AC input power
supply, make sure to use this unit's N terminal (phase)
side as the ground.
A misconnection may result in malfunction.
Caution
220 to 240 VAC
3P receptacle
Grounding terminal
PC
Connect the ground wire to the Grounding terminal.
N L
E