Appendices
A - 54
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
 
 
• This object sets the homing speed.
• Subindex 01 hex Speed during search for switch sets the operation speed to be used until the 
Home Proximity Input signal is detected.
• Subindex 02 hex Speed during search for zero sets the operation speed to be used until the home 
signal is detected.
 
 
• This object sets the acceleration and deceleration rate to be used during homing.
 
 
 
• This object sets the offset for Target position (607A hex).
• In Cyclic synchronous position mode (csp), the offset value is added to Target position (607A hex) 
for use as the target position for the control.
 
 
• This object sets the offset for Target velocity (60FF hex).
 
 
• This object sets the offset for Target torque (6071 hex).
Index 
(hex)
Sub-
index 
(hex)
Object name Setting range Unit
Defaul
t set-
ting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
6099 --- Homing 
speeds
--- --- --- --- --- --- --- Possible ---
00 Number of 
entries
--- --- 02 hex --- 1 byte 
(U8)
RO --- --- ---
01 Speed during 
search for 
switch
1 to 
2,147,483,647
Command 
unit/s
5,000 A 4 bytes 
(U32)
RW --- --- hm
02 Speed during 
search for zero
1 to 
2,147,483,647
Command 
unit/s
5,000 A 4 bytes 
(U32)
RW --- --- hm
Index 
(hex)
Sub-
index 
(hex)
Object 
name
Setting range Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
609 A --- Homing 
acceleration
1 to 
2,147,483,647
Command 
unit/s
2
1,000,000 A 4 bytes 
(U32)
RW --- Not pos-
sible
hm
Index 
(hex)
Sub-
index 
(hex)
Object 
name
Setting range Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60B0 --- Position off-
set
-2,147,483,648 
to 
2,147,483,647
Com-
mand 
unit
0 A 4 bytes 
(INT32)
W RxPDO Not pos-
sible
csp
Index 
(hex)
Sub-
index 
(hex)
Object 
name
Setting range Unit
Defaul
t set-
ting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60B1 --- Velocity off-
set
-2,147,483,648 
to 
2,147,483,647
Command 
unit/s
0 A 4 bytes 
(INT32)
W RxPDO Not pos-
sible
csp, csv
Index 
(hex)
Sub-
index 
(hex)
Object 
name
Setting 
range
Unit
Default 
setting
Data 
attri-
bute
Size Access
PDO 
map
Com-
plete 
access
Modes of 
operation
60B2 --- Torque off-
set
-5,000 to 
5,000
0.1% 0 A 2 bytes 
(INT16)
W RxPDO Not possi-
ble
csp, csv, 
cst