A - 103
 Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A-4  Sysmac Error Status Codes
A
A-4-1  Error List
084B0000 Encoder Communi-
cations Error
Illegal data was received 
from the encoder the speci-
fied number of times.
• Noise into the encoder 
cable 
• Contact failure of the signal 
line, and disconnection of 
the encoder
• Power supply undervoltage 
to the encoder
√ P. A-12 9
084D0000 Non-volatile Memory 
Hardware Error
An error occurred on the 
non-volatile memory.
•  False detection due to a 
data read error that was 
caused by excessive noise
• Non-volatile memory failure
√ P. A-13 0
18230000 Absolute Encoder 
Multi-rotation 
Counter Error
The encoder detected a 
multi-rotation counter error.
• A temporary error occurred 
in the encoder multi-rotation 
detection function due to 
vibration, impact, or con-
densation
• Encoder failure
√ P. A-13 0
18380000 System Error A hardware error due to the 
self-diagnosis and a fatal 
software error were 
detected.
• False detection due to a 
data read error that was 
caused by excessive noise
• A fatal software error was 
detected
• Hardware failure
√ P. A-13 1
183A0000 Non-volatile Memory 
Data Error
An error of data saved in the 
non-volatile memory was 
detected.
• Power interruption or noise 
occurred while parameters 
other than the safety were 
saved
• Power interruption or noise 
occurred while the motor 
identity information was 
saved
• Power interruption or noise 
occurred while safety 
parameters were saved 
√ P. A-13 1
246D0000 Motor 
Non-conformity
The Servo Drive and motor 
combination is not correct.
• The Servo Drive and motor 
combination is not correct
√ P. A-13 2
28080000 Main Circuit Power 
Supply Phase Loss 
Error
The phase loss of the main 
circuit power supply was 
detected
• Incorrect wiring, for exam-
ple the single-phase power 
supply is input to a 3-phase 
input type Servo Drive
• In the case where the sin-
gle-phase power supply is 
input to a single- and 
3-phase input type Servo 
Drive, the phase loss detec-
tion is enabled.
• The power supply voltage is 
low or insufficient
• Broken wiring of the main 
circuit power supply input
• Servo Drive failure
√ P. A-13 3
Event code 
(hex)
Event name Description Assumed cause
Level
Refer-
ence
Min
Obs
Info