Appendices
A - 124
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
 
 
 
Event name Overspeed Error Event code 08440000 hex
Meaning The encoder detected the overspeed.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection 
timing
Continuously
Error 
attributes
Level
Minor fault
Recovery
Error reset 
(after cycling 
slave power)
Log category
System log
Effects User program Continues. Operation Power drive circuit is OFF
Indicators
EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System
-defined 
variables
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
The motor is rotated by external 
forces
Take countermeasures so that the 
motor is not subjected to external 
forces if the motor is rotated by 
external forces.
Take countermeasures so that the 
motor is not rotated by external 
forces.
Encoder failure and false detec-
tion
If this event occurs repeatedly, the 
encoder is faulty. Replace the 
motor.
None
Attached 
information
None
Precautions/
Remarks
AL status code: -, Error No.: 4700 hex
Event name Encoder Memory Error Event code 08450000 hex
Description The encoder detected a non-volatile memory error.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection 
timing
Continuously
Error 
attributes
Level
Minor fault
Recovery
Error reset 
(after cycling 
slave power)
Log category
System log
Effects User program Continues. Operation Power drive circuit is OFF
Indicators
EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System
-defined 
variables
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
False detection due to a data 
read error that was caused by 
excessive noise
If this event occurs after you 
cycled the power supply, the 
encoder is faulty. Replace the 
motor.
None
Non-volatile memory failure
Encoder failure 
Attached 
information
None
Precautions/
Remarks
AL status code: -, Error No.: 4301 hex