Appendices
A - 170
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Event name Lifetime Information Corruption Warning Event code 18390000 hex
Description An error was detected in the saved lifetime information.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
At power ON
Error
attributes
Level
Observation
*1
*1. You can change the level to minor fault by using Warning Level Change 1 Selection (4020-05 hex).
Recovery
---
Log category
System log
Effects User program Continues. Operation Not affected.
Indicators
EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System
-defined
variables
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
The lifetime information corrup-
tion was detected when the
power supply was turned ON
Perform the Lifetime Information
Clear. Note that the lifetime may
not be detected correctly after the
clear operation because the value
of lifetime information is cleared. If
this event occurs repeatedly, the
area to save lifetime information is
faulty. Replace the Servo Drive.
None
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: A705 hex
Event name Data Setting Warning Event code 34E00000 hex
Description The object set value is out of the range.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
Continuously
Error
attributes
Level
Observation
*1
*1. You can change the level to minor fault by using Warning Level Change 1 Selection (4020-05 hex).
Recovery
---
Log category
System log
Effects User program Continues. Operation Not affected.
Indicators
EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System
-defined
variables
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
The object set value is out of the
range
Correct the object setting to be
within the specified range.
Correct the object setting to be
within the specified range.
Attached
information
None
Precautions/
Remarks
AL status code: -, Error No.: B000 hex