9 Details on Servo Parameters
9 - 106
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Clears the multi-rotation counter of the absolute encoder. Clear is executed by the writing of
6A646165 hex to this object.
Set the value to this object while the motor stops and it is in Servo OFF state.
Clears the Encoder Communications Error Count. Clear is executed by the writing of 1 to this object.
Gives the status of the multi-rotation counter of the absolute encoder and Encoder Communications
Error Count Clear.
Description of Set Values
Subindex F1 hex: Absolute Encoder Setup
Subindex F2 hex: Encoder Communications Error Count Clear
Subindex FF hex: Clear Status
Set value Description
Bit 0 Status of Absolute Encoder Setup
0 Clear is not executed or completed
1 Clear in execution
Bit 1 Status of Encoder Communications Error Count Clear
0 Clear is not executed or completed
1 Clear in execution